Horizon HCD700R/N, HMD700R/N Ice Machines
5
Specifications
Electrical
Separate circuit and equipment ground required.
Evaporator unit
Standard electrical: 115/60/1
Maximum fuse: 15A
Amperage: 6A
Condensing unit
Single-Phase
Electrical
208-230V, 60Hz
Maximum Circuit HVACR breaker size
15A
Minimum Circuit Ampacity
10.7A
Evaporator plumbing
§
3/8" OD push-in water inlet
§
3/4" MPT
§
3/4" vented drain line must slope a minimum of 1/4" per foot (6 mm per 30.4 cm run).
§
Drain to be hard piped and insulated.
§
Water shut-off recommended within 10 feet (3 m).
§
Follett recommends installation of Follett water filter system (part# 00130286) in ice machine inlet water line.
Ambient
Evaporator unit
Air temperature
100 F/38 C max.
50 F/10 C min.
Water temperature
90 F/32 C max.
45 F/7 C min.
Water pressure
70 psi max. (483 kPa)
10 psi min. (69 kPa)
Condenser unit
Air temperature
120 F/49 C max.
–20F/–29C min.
Refrigeration
§
3/8" liquid line
§
5/8" suction line
Note:
Rack system installations require a capacity of 6,000 BTU/hr at 0 F (–18 C) evaporator temperature.
Evaporator pressure regulator (not supplied) is required.
Weight
Evaporator unit: 125 lbs (57 kg)
Condensing unit: 225 lbs (102 kg)
Ice production
F
C
50
10
60
16
70
21
80
27
90
32
60
16
747
339
714
324
671
304
649
294
600
272
70
21
678
308
673
305
643
292
609
276
583
264
80
27
644
292
618
280
589
267
561
254
535
243
90
32
586
266
559
254
528
239
506
230
499
226
100
38
565
256
529
240
512
232
478
217
441
200
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Inlet W
ater
T
emperature F/C
Ambient Air Temperature F/C
Air-cooled ice machine capacity/24 hrs.