110CT425A/W, 110FB425A/W
3
Specifications
Electrical
§
Freestanding and countertop models (110FB425A/W, 110CT425A/W) require a dedicated circuit.
Total system
Max. circuit
Basic electrical: 115 V/60 Hz/1 phase
11.0A
20A
§
Dispensers and ice machines are supplied with 7-foot power cord with NEMA 5-15 hospital-grade plug. Connect
to a dedicated 15A circuit.
Model
Electrical connection
Circuits required
110FB425A/W
cord & plug provided
115/60/1, 15A max. fuse size
110CT425A/W
cord & plug provided
115/60/1, 15A max. fuse size
Ambient
Air temp*
100 F/38 C Max.
50 F/10 C Min. (Best performance below 80 F/27 C)
Water temp
†
90 F/32 C Max.
45 F/7.2 C Min. (Best performance below 70 F/21 C)
Water pressure (psi/bar)
70/5 Max.
10/0.7 Min.
*
Ambient air temperature is measured at the air-cooled condenser coil inlet.
†
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
110CT with integral ice
machine
110FB with ice machine
in base
Dispenser drain
3/4" MPT
3/4" MPT
Ice machine drain
3/4 MPT
3/4" MPT
Dispenser water inlet
3/8" FPT
3/8" FPT
Ice machine water inlet
3/8" FPT
—
Cond. inlet – w/c only
3/8" FPT
3/8" FPT
Cond. drain – w/c only
3/8" FPT
3/8" FPT
Note:
Water shut-off recommended within 10 ft (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
§
110CT425A/W:
6" (15.2 cm) required at top.
Note:
6" (15.2 cm) at each side advised for service.
§
110FB425A/W:
4" (10.2 cm) required at rear .
Note:
12" (30.5 cm) at top advised for service.
Approximate shipping weight
§