ADJUSTMENTS (Continued)
POTENTIOMETER ADJUSTMENTS TRAVERSE DRIVE CONTROL (TDC)
Min. Speed--Factory set at full (CCW) 8:30. Do not change this setting.
(Right Traverse) Forward Torque--Factory set at full (CW) 4:30. Do not change this setting.
(Left Traverse) Reverse Torque--Factory set at full (CW) 4:30. Do not change this setting.
IR COMP--Factory set to 9:00. Regulation of a traverse motor may be improved by slight adjustment of the IR
COMP trim pot clockwise from its factory-set position. Overcompensation causes the motor to oscillate or to
increase speed when fully loaded. If you reach such a point, turn the IR COMP trim pot counterclockwise until
the symptoms disappear.
Max. Speed--Set at 3:30 for maximum voltage of 90 Volts DC to the traverse motor. When voltage is above 90
volts DC, the traverse motor will start to pulsate and not run smoothly.
(Right Traverse) Forward Acceleration--Factory set at full (CCW) 8:30. Do not change this setting.
(Left Traverse) Reverse Acceleration--Factory set at full (CCW) 8:30. Do not change this setting.
(DB) Dead Band is the potentiometer setting for the 50 or 60 Hz cycle control. Factory set to 9:00, works for
both 50 and 60 Hz. Do not change this setting.
Calibrating the DWELL TIME rotary DIP switch adjusts the amount of time the process remains in the stop
position after a limit switch is actuated. The DWELL TIME range is adjustable from 0 - 4 seconds. A DIP switch
setting of 0 sets the DWELL TIME to 0 seconds, while a setting of 9 sets the DWELL TIME to 4 seconds.
Dwell time is preset to #2 setting for a 1 second dwell time when reversing at each end of stroke. A setting of 4,
sets the dwell time at 2 seconds, etc.
Diagnostic LED's indicate the function that is currently being performed:
*
POWER indicates that ac power is being applied to the control.
*
FORWARD indicates that the process is running in the forward direction (traversing left).
*
REVERSE indicates that the process is running in the reverse direction (traversing right).
*
PROX 1 FWD LIMIT lights when the forward
limit switch is actuated (left prox).
*
PROX 2 REV LIMIT lights when the reverse limit
switch is actuated (right prox).
*
DWELL lights when the process remains
stopped after a proximity switch is actuated.
3:00
9:00
6:00
12:00
Potentiometer
Clock Orientation
Summary of Contents for ACCU-Pro 670
Page 34: ...34 ELECTRIC SCHEMATIC 67095233...
Page 35: ...35 This Page Left Intentionally Blank for Note Taking Purposes...
Page 36: ...36 PARTS LIST 6709528 MAIN BASE ASSEMBLY...
Page 38: ...38 PARTS LIST Continued 6709529 GRINDING HEAD ASSEMBLY...
Page 40: ...40 PARTS LIST Continued 6709520 TRAVERSE CARRIAGE ASSEMBLY...
Page 42: ...42 PARTS LIST Continued 6709524 BEDKNIFE SUPPORT ASSEMBLY...
Page 44: ...44 PARTS LIST Continued 6709523 CONTROL PANEL ASSEMBLY 50 51...
Page 46: ...46 PARTS LIST Continued 6709523 ELECTRICAL ASSEMBLY...
Page 48: ...48 PARTS LIST Continued 7469909 COOLANT PUMP TANK ASSEMBLY 15...
Page 50: ...50...