8
ASSEMBLY INSTRUCTIONS (Continued)
FIG. 7
APPLY POWER
BEFORE YOU APPLY POWER TO THE
GRINDER, REFER TO THE "IMPORTANT
GROUNDING INSTRUCTIONS" ON PAGE 9.
115 Volt Model Only. Plug the control box power cord into a
standard 115V AC 15-amp grounded receptacle. See FIG. 7.
220 Volt Model Only. For 220 Volt Applications order Part
No. 6700951, which includes a 220 to 110 Volt Step Down
Transformer. See Details on page 9.
IT IS RECOMMENDED THAT THIS ACCU-
PRO BEDKNIFE GRINDER HAS ITS OWN
PERMANENT POWER CONNECTION FROM
THE POWER DISTRIBUTION PANEL, WITH
NO OTHER MAJOR POWER DRAW
EQUIPMENT ON THE SAME LINE.
IT IS REQUIRED THAT THE POWER
DELIVERED TO THIS GRINDER IS 115 VAC -
15 AMPS. THE TOLERANCE ON THIS
POWER REQUIREMENT IS +/- 5%.
THEREFORE THE MINIMUM VOLTAGE
REQUIREMENT IS 109VAC WITH 15 AMPS.
VOLTAGE MUST BE CHECKED WITH ALL
EQUIPMENT UNDER LOAD (OPERATING) ON
THE CIRCUIT.
DO NOT OPERATE THIS GRINDER WITH
AN EXTENSION CORD.
The grinder is equipped with a low voltage relay
which is factory preset at 100 VAC. If the power
supply line does not deliver 100 VAC power under
load, the relay will open and trip out the starter. If
this occurs, your power supply line is inadequate
and must be correct before proceeding further with
the grinder.
ADJUSTMENT OF THE LOW
VOLTAGE RELAY MAY CAUSE
ELECTRICAL COMPONENT
FAILURE. ADJUSTMENT OF
THE LOW VOLTAGE RELAY
WILL VOID ALL ELECTRICAL
COMPONENT WARRANTY.
PROPER GROUNDING OF THE RECEP-
TACLE GROUND IN YOUR BUILDING MUST
BE VERIFIED. IMPROPER GROUNDING IN
YOUR BUILDING MAY CAUSE THE GRINDER
TO MALFUNCTION.
FOR 15 AMP RATED LARGE MACHINES
For 0 to 30 Feet from panel to receptacle = Use 14 Ga. Wire.
For 30 to 50 Feet from panel to receptacle = Use 12 Ga. Wire.
For 50 to 80 Feet from panel to receptacle = Use 10 Ga. Wire.
For 80 to 140 Feet from panel to receptacle = Use 8 Ga. Wire.
For 0 to 9 Meters from panel to receptacle = Use 2.5mm Wire.
For 9 to 15 Meters from panel to receptacle = Use 4.0mm Wire.
For 15 to 24 Meters from panel to receptacle = Use 6.0mm Wire.
For 24 to 42 Meters from panel to receptacle = Use 10.0mm Wire.
Summary of Contents for ACCU-Pro 670
Page 34: ...34 ELECTRIC SCHEMATIC 67095233...
Page 35: ...35 This Page Left Intentionally Blank for Note Taking Purposes...
Page 36: ...36 PARTS LIST 6709528 MAIN BASE ASSEMBLY...
Page 38: ...38 PARTS LIST Continued 6709529 GRINDING HEAD ASSEMBLY...
Page 40: ...40 PARTS LIST Continued 6709520 TRAVERSE CARRIAGE ASSEMBLY...
Page 42: ...42 PARTS LIST Continued 6709524 BEDKNIFE SUPPORT ASSEMBLY...
Page 44: ...44 PARTS LIST Continued 6709523 CONTROL PANEL ASSEMBLY 50 51...
Page 46: ...46 PARTS LIST Continued 6709523 ELECTRICAL ASSEMBLY...
Page 48: ...48 PARTS LIST Continued 7469909 COOLANT PUMP TANK ASSEMBLY 15...
Page 50: ...50...