background image

ENGLISH

4

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of malfunction or breakdown, 

grounding provides a path of least resistance for electric current to reduce the 

risk of electric shock. This appliance is equipped with a cord having an 

equipment-grounding conductor and a grounding plug. The plug must be plugged 

into an appropriate outlet that is properly installed and grounded in accordance 

with all local codes and ordinances.

DANGER 

– 

Improper connection of the equipment-grounding conductor 

can result in a risk of electric shock. The conductor with insulation having an 

outer surface that is green with or without yellow stripes is the equipment-

grounding conductor. If repair or replacement of the cord or plug is necessary, do 

not connect the equipment-grounding conductor to a live terminal.

 Check with a qualified electrician or serviceman if the grounding instructions are 

not completely understood, or if there is any doubt as to whether the outlet box 

and the appliance is properly grounded. Do not modify the plug provided with the 

appliance – if it will not fit the outlet, have a proper outlet installed by a qualified 

electrician.

USER MAINTENANCE INSTRUCTIONS

We recommend that the machine be returned to an authorized Distributor or 

Service Center for repairs. However, users may undertake maintenance if they 

wish. The Instruction Manual contains information on common repair procedures.

DANGER 

- RISK OF ELECTRIC SHOCK. Remove electrical plug 

from outlet before attempting any service. Do not unplug by pulling on 

cord. To unplug, grasp the plug, not the cord.

SAVE THESE INSTRUCTIONS

Summary of Contents for VECTRA-JET 750510CE

Page 1: ...ENGLISH INSTRUCTION MANUAL VECTRA JET FOGGER Models 750510CE 750520CE READ AND SAVE THESE INSTRUCTIONS W90017505EN 04 1508...

Page 2: ...accordance with EN55014 CISPR 14 1 2001 and CISPR 14 2 2001 Compatibility with World Electrical Systems Fogger motors and cord options KUE xxx are available for most electrical supply systems and sock...

Page 3: ...4 Do not unplug by pulling on cord To unplug grasp the plug not the cord 5 Unplug from outlet when not in use and before servicing or cleaning 5 Do not operate any appliance with a damaged cord or plu...

Page 4: ...r replacement of the cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or serviceman if the grounding instructions are no...

Page 5: ...this information obtain directions for use and safety precautions including personal protective equipment respirator face mask special clothing from the chemical manufacturer or distributor Keep an in...

Page 6: ...izers scents or masking chemicals Humidification fogging water The liquid flow rate determines the size of the fog droplets produced Several factors influence liquid flow rate the setting of the flow...

Page 7: ...el or information sheet Fogs are useful for this application because they diffuse widely use less chemical and speed up drying Measuring the Liquid Flow Rate Adjust the angle of the nozzle for your ap...

Page 8: ...The top of the liner should extend over and outside the top lip of the tank NOTE Although the stainless steel of the Vectra Jet fogger offers a measure of protection against chemical corrosion we none...

Page 9: ...dden movements can impose excessive torque on the rapidly spinning fan blades and could cause premature blade failure Cleaning the Fogger A Normal cleanup When fogging is complete unclamp power head a...

Page 10: ...he nozzle Deposits that form on the nozzle can degrade atomization perfor mance Try to dissolve deposits with an appropriate mild solvent soapy water vinegar solution kerosene Lime Away etc Add about...

Page 11: ...ss the motor Identify the two motor brush housings on opposite sides at the top of the motor Insert a small flat blade screwdriver between the motor wire termi nal and the plastic brush housing Gently...

Page 12: ...s and torque ring in proper sequence The bent tab on the torque ring must face the motor and be seated in the small hole on the motor frame Reconnect electrical lines as shown on the circuit diagram R...

Page 13: ...0 60 Hz 200 240V MODELS STANDARD UNIT CORD PLUG WITH EARTH to 220 240VAC 50 60 Hz GROUND RIVET BLUE BROWN M BLACK WHITE 100 120V MODELS STANDARD UNIT GREEN M GREEN BLUE GREEN POWER HEAD HOUSING EMI FI...

Page 14: ...crons adjustable Liquid viscosity and surface tension affect droplet size Control Valve Nine turn vernier w memory lock Glass filled epoxy stainless stem Viton seals Liquid Capacity 1 gallon 4 L Blowe...

Page 15: ...his warranty is limited to the original purchaser only and does not include claims for incidental or consequential damages resulting from the non function or malfunction of this product or for breach...

Page 16: ...r respective owners In the interest of improving internal design operational function and or reliability The Fogmaster Corporation reserves the right to make changes to the products described in this...

Reviews: