CONTROL PANEL DISPLAY
The System status can be viewed on the various pages of the control panel display. Push the
key on
the keypad to select the page to view.
PAGE 1
SYS
(System): shows if the system is in Manual (MAN) or Automatic (AUT) mode
EV
(Electric Valve): shows if the electric valves (1,2,3) are On (1) or Off (0).
ACQ
(Acquisition): shows the positions of the acquired rotation points; (0) the machine will search for the 0
point; (1) first point of the angle; (2) second point of the angle.
PAGE 2
PMP
(PUMP): Shows if the pump is Off (OFF), On (MAN) or in Auto (AUT)
RADIO
(RADIOCOMAND): Shows if the radio is On (ON) or Off (OFF)
HEATER
(HEATING SYSTEM): Shows if the heater is On (ON) or Off (OFF).
PAGE 3
TIM
(TIMER WORK/PAUSE): Shows if the timer is On (ON) or Off (OFF)
TIM.ON
(WORKING TIME) The first column shows the working time in minutes (from 5 to 30 minutes). If the
timer is On, the second column shows the remaining On time.
TIM.OFF
(PAUSE TIME) The first column shows the pause time in minutes (from 5 to 30 minutes). If the
timer is On, the second column shows the remaining pause time.
CONTROL PANEL BUTTONS
Turns the fan ON or OFF. Also turns the pump ON or OFF if the pump is in AUTO mode.
Turns the system to AUTO or MANUAL mode.
Turns the pump OFF, AUTO, or ON.
AUTO is the recommended default setting.
Raises the cannon if fitted with Electric Tilt.
Changes the Page view between pages 1, 2, and 3.
Turns the electric valve for zone 1 ON or OFF (1/0) if fitted with Electric Valves.
Turns the Radio Control ON/OFF if fitted with REMOTE CONTROL.
Oscillates the cannon to the left.