TECHNICAL DATA 
 

 

 

 

 

Description 

 

HD 160  

HD 230  

HD300   

Volts   

 

Fan Motor HP   

7.5 

 

15 

 

25 

 

480 VAC / 60 Hz 

Pump Motor HP 

 

 

 

480 VAC / 60 Hz 

Oscillation Motor HP 

.1 

 

.1 

 

.1 

 

24 VDC 

Full Load Amps  

21 

 

32 

 

45 

 

 

 

STANDARD SUPPLY 

 
The machine is supplied ready for use and includes the User’s Manual and Data plate with Machine 
technical information; 

 
GENERAL SAFETY WARNINGS 
 

 

 
 
 
The manufacturer has done his utmost in designing this Machine to be INTRINSICALLY SAFE and is fitted 
with all necessary protective and safety devices and is supplied with the information for its proper use. 
 
The user can appropriately integrate the information provided by the manufacturer with supplementary work 
instructions to ensure safe use of the Machine and must not be in contrast with the instructions given in this 
Manual,  
 

  It is forbidden to operate the Machine in Auto mode with the fixed/mobile protection devices dismantled; 

 

  It is forbidden to inhibit the safety devices installed on the Machine; 

 

  It is forbidden to stand in front of the Machine when it is in operation; 

 

  Before carrying out any repair or maintenance, the Machine must be switched off and disconnected from 

the water and power supply networks; 

 

  All maintenance operations must be performed by qualified and authorized staff; 

 

  It is mandatory to wear the necessary personal protection devices; 

 

  It is mandatory to respect and observe all alarms and warnings; 

 

  In  the  event  of  a  malfunction  of  a  component,  the  failed  component  must  be  replaced  with  and  exact 

duplicate.  The manufacturer shall not be held liable for the consequences when generic parts are used 
to replace factory authorized parts.  Modification requests must be directed to the manufacturer; 

 

  Clean  the  machine,  panels  and  controls  with  soft  dry  cloth  or  slightly  soaked  in  a  neutral  detergent 

solution.  Do not use any type of solvent, such as alcohol or petrol, as the surfaces could be damaged; 

 

  The washing operations must be performed with the electrical and pneumatic separation devices cut off; 

it’s strictly forbidden to use high pressure systems for washing the machine and/or its inner parts.  

 

 

It is absolutely forbidden to move the machine when operating with lifting means 
of  any  nature  and  kind.  The  machine  can  be  moved  exclusively  with  hydraulic 
and  electrical  devices  uncoupled  and  the  frame  must  be  blocked  with  the 
appropriate  pins  to  the  lift  forks.  The  spring  pins  must  be  inserted  into  the 
blocking pins. 

 

 

USE POTABLE WATER ONLY 

Before  putting  the  Machine  into  operation  carefully  read  the  instructions  set  out  in  this 
Manual and follow the indications provided in it. 

Summary of Contents for FogCannon HD 160

Page 1: ...co FogCannon HD 160 HD 230 HD 300 Pole Trailer FOGCO Environmental Solutions 600 S 56th Street Chandler AZ 85226 Phone 800 607 6478 Fax 480 838 2232 Website www fogco com e mail info fogco com Rev0808...

Page 2: ...or 1st level operator without specific skill able to perform only simple tasks such as the operation of the machine using the buttons on the Machine panel or Remote operations of loading and unloading...

Page 3: ...shroom or part to use Machine in movement with automatic function mobile protection guards closed with relevant blocking device activated and fixed protector guards closed Machine in movement mobile p...

Page 4: ...Name Dangerous electrical tension Crushing of upper limbs Getting caught Dragging Access forbidden to unauthorized persons Do not remove safety devices Prohibited to clean oil grease repair or adjust...

Page 5: ...the manufacturer shall void the warranty and the manufacturer shall not be held liable for damage caused by the faulty product ARRANGEMENTS TO BE PROVIDED BY CUSTOMER The following are the sole respon...

Page 6: ...manually or in Remote mode serve to adjust the rotation angle and to make the fogcannon work within the selected angles set up at the user s own discretion Filter The unit is fitted with a 100 mesh f...

Page 7: ...E 3 TIM TIMER WORK PAUSE Shows if the timer is On ON or Off OFF TIM ON WORKING TIME The first column shows the working time in minutes from 5 to 30 minutes If the timer is On the second column shows t...

Page 8: ...on by loosening the cannon Tilt Handle located on the tilt assembly next to the main control panel raise or lower the cannon as needed tighten the Tilt Handle Manually open close the valves for the in...

Page 9: ...pped with Electric Tilt To terminate the operation press the FAN key once and press the appropriate Electric Valve and or keys once or rotate the manual zone valves if the unit is not equipped with El...

Page 10: ...tely and run until the PMP is set to OFF NOTE The Electric Valves will NOT be automatically activated whenever the pump is running They must be turned on seperately by pressing the appropriate EV key...

Page 11: ...he crown can be operated seperately or simultaneously creating a wide range of flow options for the unit The table below provides approximate flow given the standard nozzles and the number of zones be...

Page 12: ...had not been set up SOLUTION Follow the SET THE ROTATION ANGLE instructions above This alarm indicates that the pump is not supplied with enough water The pump stops and the red and yellow Tower Light...

Page 13: ...CUIT BREAKER When the machine is stopped with the emergency stop it requires to switch on the circuit breaker with the following procedure Restore the emergency stop Dismount the front protection usin...

Page 14: ...Remove the front protection and switch off the main switch white arrow Open the electric cabinet and look for the blue colored circuit breaker orange arrow...

Page 15: ...Lift up the switch as shown in picture blue arrow Close the electric cabinet and the front protection Switch on the main switch white arrow...

Page 16: ...dity ranging from 30 to 95 The machine may not be used in environments with A corrosive atmosphere A risk of fire An explosive atmosphere A risk of stones being ejected Water and chemical substances t...

Page 17: ...ce operations must be performed by qualified and authorized staff It is mandatory to wear the necessary personal protection devices It is mandatory to respect and observe all alarms and warnings In th...

Page 18: ...s to the manufacturer The Machine must be taken out of service until operating anomalies are verified and corrected or repaired Certify that there are no objects between the Machine parts Check that n...

Page 19: ...NGEROUS ZONES Dangerous zones include but are not limited to electrical substation or areas where there are electrical parts with IP level lower than IP 55 and or areas where there is the risk of expl...

Page 20: ...socket Disassemble the nozzles using a 5 8 socket wrench and a 5 32 Allen wrench Brush slots on the top of the nozzle inserts with a stainless steel wire brush to remove all debris Remove the O ring...

Page 21: ...Maintenance executed Date Done by Notes...

Page 22: ...Maintenance executed Date Done by Notes...

Page 23: ...An explanation of the defect or problem a description of the way in which the FogCannon is used the customers name address and telephone number the FogCannon model number and the serial number must b...

Page 24: ...______________________________ FogCannon serial number on metal tag ______________________________________ Manufacture date on metal tag _____________________________________________ Are you intereste...

Reviews: