3. DIMENSIONS
MODEL
WEIGHT (Lbs)
DIMENSIONS (inches)
H
L
W
HD 160
Pole with iron base
1455
103
48
48
HD 160 T
railer
950
88
98
75
HD 230 P
ole with iron base
1630
103
48
52
HD 230
Trailer
1125
88
98
75
HD 300 P
ole with iron base
1720
103
48
52
HD 300
Trailer
1215
103
98
75
ENVIRONMENTAL CONDITIONS
The Machine does not need to work in specific environmental conditions. It can be installed in an industrial
building where the electrical equipment has at least IP55 protection, the ventilation is good and the floor is
solid and level.
ATTENTION – the machine must not be used in environments with an explosive or corrosive atmosphere.
The machine may be used in environments with:
Temperatures between 40° F and 100° F, with a mean temperature of 90° F;
Relative humidity ranging from 30 to 95%.
The machine may not be used in environments with:
A corrosive atmosphere;
A risk of fire;
An explosive atmosphere;
A risk of stones being ejected;
Water and chemical substances that could mix and create hazards.
LIGHTING
The installation area must be illuminated in accordance to the local codes or regulations in force. The lighting
should ensure good all-round visibility, create no dangerous reflections, make it possible to read the writing
on the control panels clearly and easily and locate the emergency buttons without trouble.
VIBRATIONS
The vibrations do not generate any risk of danger if the machine is used properly according to the manual
instruction. If you are planning to install the machine in an area where there is a strong risk of vibration, you
should fit vibration dampeners of adequate size between the machine and the source of vibration. The
dampeners require a written declaration of approval issued by Fogco.