SETTING THE TIMER  

 
It is possible to set up TIME ON and TIME OFF times for the system. 

Press the 

 PAGE key on the keypad to select Page 3.  

Press the 

TIM ON key to increase the TIME ON setting (left-hand column) in 5-minute increments from 5 

to 30 minutes.  

Press the 

 TIM OFF key to increase the TIME OFF setting (left-hand column) in 5-minute increments 

from 5 to 30 minutes.  

After setting the TIM ON and TIM OFF, the timer can be activated by pushing the 

 TIMER key.  

 
While the machine is operating, the value in the right-hand column for the TIM.ON decreases starting from 
the maximum value shown on the left until 0 is reached. Identical procedure is valid for the pause time. 
 

 
SETTING THE PUMP FUNCTION 

 
Use the 

 key on the keypad to toggle between the 3 pages  

Check the settings on Page 1.  SYS should be MAN and all EV should be set to 0;  
Check the settings on Page 2.  PMP should be OFF and Radio should be OFF 
Check the settings on Page 3.  TIM should be OFF 
 
Press the 

 PUMP key to switch between OFF, AUT, and MAN 

When the PMP is set to OFF, it will be deactivated. 
When the PMP is set to AUT, it will start automatically whenever the fan is activated and will continue to run 
until the fan operation is terminated.   
When the PMP is set to MAN, it will start immediately and run until the PMP is set to OFF.   
 

NOTE: The Electric Valves will NOT be automatically activated whenever the pump is running.  They must 
be turned on seperately by pressing the appropriate EV key on the keypad. The electric valves will NOT be 
deactivated when the pump is turned OFF.  They must be turned OFF manually by pressing the appropriate 
EV key on the display.   

 

 

SETTING RADIO CONTROL 

 
Transmitter Button controls: 
First Row: Tilt UP and DOWN 
Second Row: Oscillate Left and Right 
Third Row: Fan ON/OFF and Electric Valve 1 ON/OFF 
Fourth Row: Electric Valve 2 ON/OFF and Electric Valve 3 ON/OFF 
Fifth Row:Not Used 
Sixth Row: ON/SYSTEM AUTO mode and Pump ON/OFF 
 
Use the 

 PAGE key to toggle between the 3 pages.   

Check the settings on Page 1.  SYS should be in MAN; and all EV should be set to 1.  
Check the settings on Page 2.  PMP should be AUTO and Radio should be OFF. 
Check the settings on Page 3.  TIM should be OFF. 
Press the 

  key on the keypad to select the page 2. 

Press the 

 RADIO key to switch from OFF to ON.   

Once the RADIO on the machine control panel is set to ON, only the PAGE and RADIO keys will function. 
Insert a fully charged battery into the Radio Transmitter 
Pull out the red tab on the top of the Transmitter. 
Briefly press the Transmitter ON button (bottom left hand position on the Transmitter) 
Then hold the same button down until the LED light begins flashing green. 
The transmitter is now ready to use and provides the following functions: 
 

Summary of Contents for FogCannon HD 160

Page 1: ...co FogCannon HD 160 HD 230 HD 300 Pole Trailer FOGCO Environmental Solutions 600 S 56th Street Chandler AZ 85226 Phone 800 607 6478 Fax 480 838 2232 Website www fogco com e mail info fogco com Rev0808...

Page 2: ...or 1st level operator without specific skill able to perform only simple tasks such as the operation of the machine using the buttons on the Machine panel or Remote operations of loading and unloading...

Page 3: ...shroom or part to use Machine in movement with automatic function mobile protection guards closed with relevant blocking device activated and fixed protector guards closed Machine in movement mobile p...

Page 4: ...Name Dangerous electrical tension Crushing of upper limbs Getting caught Dragging Access forbidden to unauthorized persons Do not remove safety devices Prohibited to clean oil grease repair or adjust...

Page 5: ...the manufacturer shall void the warranty and the manufacturer shall not be held liable for damage caused by the faulty product ARRANGEMENTS TO BE PROVIDED BY CUSTOMER The following are the sole respon...

Page 6: ...manually or in Remote mode serve to adjust the rotation angle and to make the fogcannon work within the selected angles set up at the user s own discretion Filter The unit is fitted with a 100 mesh f...

Page 7: ...E 3 TIM TIMER WORK PAUSE Shows if the timer is On ON or Off OFF TIM ON WORKING TIME The first column shows the working time in minutes from 5 to 30 minutes If the timer is On the second column shows t...

Page 8: ...on by loosening the cannon Tilt Handle located on the tilt assembly next to the main control panel raise or lower the cannon as needed tighten the Tilt Handle Manually open close the valves for the in...

Page 9: ...pped with Electric Tilt To terminate the operation press the FAN key once and press the appropriate Electric Valve and or keys once or rotate the manual zone valves if the unit is not equipped with El...

Page 10: ...tely and run until the PMP is set to OFF NOTE The Electric Valves will NOT be automatically activated whenever the pump is running They must be turned on seperately by pressing the appropriate EV key...

Page 11: ...he crown can be operated seperately or simultaneously creating a wide range of flow options for the unit The table below provides approximate flow given the standard nozzles and the number of zones be...

Page 12: ...had not been set up SOLUTION Follow the SET THE ROTATION ANGLE instructions above This alarm indicates that the pump is not supplied with enough water The pump stops and the red and yellow Tower Light...

Page 13: ...CUIT BREAKER When the machine is stopped with the emergency stop it requires to switch on the circuit breaker with the following procedure Restore the emergency stop Dismount the front protection usin...

Page 14: ...Remove the front protection and switch off the main switch white arrow Open the electric cabinet and look for the blue colored circuit breaker orange arrow...

Page 15: ...Lift up the switch as shown in picture blue arrow Close the electric cabinet and the front protection Switch on the main switch white arrow...

Page 16: ...dity ranging from 30 to 95 The machine may not be used in environments with A corrosive atmosphere A risk of fire An explosive atmosphere A risk of stones being ejected Water and chemical substances t...

Page 17: ...ce operations must be performed by qualified and authorized staff It is mandatory to wear the necessary personal protection devices It is mandatory to respect and observe all alarms and warnings In th...

Page 18: ...s to the manufacturer The Machine must be taken out of service until operating anomalies are verified and corrected or repaired Certify that there are no objects between the Machine parts Check that n...

Page 19: ...NGEROUS ZONES Dangerous zones include but are not limited to electrical substation or areas where there are electrical parts with IP level lower than IP 55 and or areas where there is the risk of expl...

Page 20: ...socket Disassemble the nozzles using a 5 8 socket wrench and a 5 32 Allen wrench Brush slots on the top of the nozzle inserts with a stainless steel wire brush to remove all debris Remove the O ring...

Page 21: ...Maintenance executed Date Done by Notes...

Page 22: ...Maintenance executed Date Done by Notes...

Page 23: ...An explanation of the defect or problem a description of the way in which the FogCannon is used the customers name address and telephone number the FogCannon model number and the serial number must b...

Page 24: ...______________________________ FogCannon serial number on metal tag ______________________________________ Manufacture date on metal tag _____________________________________________ Are you intereste...