Pos.

Quantity Description

1

2

Nut DIN 985

2

1

Reinforcing plate L. H.

3

1

Reinforcing plate R. H.

4

1

Charge indicator 12 V

5

14

Nut DIN 985

6

2

Cup square bolt M12x50

7

2

Nut DIN 934

8

2

Spacer

9

1

Automatic nozzle valve - urea - stainless steel

10

1

Nozzle holder - white

11

1

Control panel assy. 

12

1

Covering assy.

13

1

Supporting plate assy.

14

1

Automatic charger

15

1

Double nipple, urea

16

1

Pulse meter - G 1" fem-G 1" fem-urea, oval gear meter - stainless steel

17

1

Urea electric diaphragm pump 30 l/min-7,9 gpm-12 V-DC

18

1

AGM lead accumulator

19

2

Castor with total lock

20

2

Shaft

21

2

Solid rubber tyre

22

1

Trolley frame

23

1

Handle, upper part, assy. 

24

19

Screws with flattened half round head and collar M5x10

25

1

Rocker switch, green

26

6

Countersunk screw M 4x12

27

1

Counternut for potentiometer

28

4

Cylinder screw M 6x12

29

4

Shim DIN 9021

30

4

Fillister head screw M 3x8

31

4

Spacer

32

2

Fillister head screw M 3x5

33

2

Bend 90° with fitting - urea

34

3

Hexagon nut DIN985

35

4

Fillister head screw M 4x6

36

4

Washer

37

1

Rotary knob with pointer

38

1

Support bracket, height 28.5 mm for NUMERIxx

39

1

Board NUMERIxx digital

40

1

Plug C14

41

1

Cable duct 18x30x400

42

1

Control unit mobiSERVE

43

1

Fastening clip

44

2

Fillister head screw M 3x6

45

1

Cylinder screw M 4x6

Tab. 17-1: Overview of components for fig. 17-1

Summary of Contents for mobiSERVE

Page 1: ...81 231 932 A801 GB OPERATING INSTRUCTIONS AND SAFETY NOTES mobiSERVE Mobile with battery...

Page 2: ...licated or distributed neither in full or in part utilized for the purpose of competition or passed on made availabe to third parties FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbestra e...

Page 3: ...___________12 8 1 Discharge in normal mode_____________________________________________________________13 8 1 1 Resetting the partial amount___________________________________________________________1...

Page 4: ...l provisions as well as all other binding rules regarding occupational safety accident prevention and environmental protection Wear appropriate protective clothing in accordance with the work to be do...

Page 5: ...otes lists a The arrow identifies cross references If cross references to other chapters are required within the text the expres sion is shortened for reasons of clarity Example a Chapter 2 Safety ins...

Page 6: ...se The mobiSERVE urea conveying system has been designed for conveying urea solutions urea AdBlue or water from mobile tanks into containers provided for this purpose for example vehicle tanks The ure...

Page 7: ...use please note the details in ZH 1A45 4 2 or DIN 20066 Part 5 3 2 Escaping liquids can cause environmental harm Comply with the stipulations of the German Water Resources Act WHG and of the Plant Reg...

Page 8: ...display of the mobiSERVEs is equipped with two numerical registers and various screens which only appear if needed by the current function Legend 1 Register of the partial amount 5 digits with floati...

Page 9: ...utes after the main switch has been turned off Measuring chamber The measuring chamber is located in the middle part of the unit The measuring chamber is equipped with oval gears When rotating these o...

Page 10: ...rings are not damaged at the connection For an exchange of barrels proceed in reverse order 60 liter mobiSERVE 25 353 The 60 l trolley is equipped with a plastic container The suction hose and the con...

Page 11: ...SERVE is equipped with a flow rate control unit The infinitely variable flow rate can be adapted to the vehicle to be filled To do this turn the rotary knob Flow Rate in the range from min to max The...

Page 12: ...done automatically and is performed within a period of time defined during manufacturing It cannot be changed by the user Register of RESETTABLE TOTAL VOLUME Register of ABSOLUTE TOTAL VOLUME Registe...

Page 13: ...absolute total amount The message RESET over the word TOTAL goes out and the value of the resettable total amount is replaced by the absolute total amount This state is called pause or standby and rem...

Page 14: ...g which all segments are switched off followed by the display of the reset total amount RESET TOTAL 8 1 3 Discharge with display of the current flow rate Flow Rate Mode During discharge operations the...

Page 15: ...g in the normal mode the counter will in this case not go through the phase during which all display segments are successively switched on and off but will immediately show the register of the partial...

Page 16: ...and total discharge amount data are retained even without power supply After the battery has been replaced a new calibration is not necessary 9 4 Display of the current calibration factor and if requ...

Page 17: ...ring container under realistic operation conditions flow rate viscosity which must be strictly adhered to The following points must be observed for a correct calibration of the counter Completely blee...

Page 18: ...r Carry out the procedure correctly as described in the folowing 9 4 2 Calibration procedure during operation Operation Display Configuration 1 NONE Counter in normal mode not counting 2 LONG PRESS ON...

Page 19: ...xample 9 800 must be brought to the actual value indicated by the calibrated container On the lower left corner of the display an arrow appears pointing upwards or downwards thus indicating the direct...

Page 20: ...some seconds then the restart procedure is repeated in order to finally get into the standby mode ATTENTION From that moment the value indicated is the new calibration factor used by the counter and i...

Page 21: ...ayed instead of the partial amount The messages FACT or USER on the screen indicate which one of the two factors is currently being used user or manufacturer 3 LONG PRESS ON THE RESET KEY The counter...

Page 22: ...some seconds then the restart procedure is repeated in order to finally get into the standby mode ATTENTION From that moment the value indicated is the new calibration factor used by the counter and...

Page 23: ...le and absolute total amounts are automatically converted into the new measuring units Changing the measuring unit DOES NOT require a new calibration 11 Preventive maintenance The mobiSERVE has been d...

Page 24: ...quality standards Should a problem develop despite of all quality controls please contact our customer service FMT Swiss AG Tel 49 9462 17 216 Fax 49 9462 1063 service fmtag ch 15 Disposal The operat...

Page 25: ...AdBlue or water Complies with all relevant provisions of the following directives EC Directives 2006 42 EC Machinery Directive 2014 30 EC EMC Directive 2011 65 EC EC Directive RoHS Applicable standar...

Page 26: ...26 GB Operating instructions mobiSERVE 17 Exploded view of mobiSERVE 200 l Fig 17 1 Exploded view of mobiSERVE 200 l...

Page 27: ...2 Castor with total lock 20 2 Shaft 21 2 Solid rubber tyre 22 1 Trolley frame 23 1 Handle upper part assy 24 19 Screws with flattened half round head and collar M5x10 25 1 Rocker switch green 26 6 Co...

Page 28: ...28 GB Operating instructions mobiSERVE 18 Exploded view of mobiSERVE 60 l Fig 18 1 Exploded view of mobiSERVE 60 l...

Page 29: ...tor with total lock 20 2 Shaft 21 2 Solid rubber tyre 22 1 Trolley frame 23 1 Handle upper part assy 24 19 Screws with flattened half round head and collar M5x10 25 1 Reinforcing plate L H 26 1 Rocker...

Page 30: ...30 GB Operating instructions mobiSERVE...

Page 31: ...31 Operating instructions mobiSERVE GB...

Page 32: ...FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbestra e 6 6330 Cham Schweiz Tel 41 41 712 05 37 Fax 41 41 720 26 21 info fmtag com www fmtag com...

Reviews: