14
GB
Operating instructions - mobiSERVE
8.1.2 Resetting the resettable total amount RESET TOTAL
The resettable total amount can only be reset to zero after previously
having reset the partial amount register to zero. The total amount
is reset by pressing on the RESET key for a longer time, while the
message RESET TOTAL is shown on the display, as on the following
screen:
The following steps are to be carried out schematically:
■
■
Wait until the normal standby screen appears (only the total
amount TOTAL is displayed).
■
■
Press shortly the RESET key. After this operation, the partial amount
reset to zero and RESET TOTAL are shown at first.
■
■
The counter begins the resetting operation of the partial amount.
■
■
While RESET TOTAL is shown on the display, press the RESET key
once again for at least one second.
■
■
The display will show all segments again, then comes the phase,
during which all segments are switched off, followed by the display
of the reset total amount RESET TOTAL.
8.1.3 Discharge with display of the current flow rate (Flow Rate Mode)
During discharge operations, the following displays may simultaneously appear:
- Partial amounts discharged
- Current flow rate in (measuring unit of the partial amount/min) as shown in the following.
Procedure to get into this mode:
■
■
Wait until the counter is in the standby mode, i.e. until the display only shows the total amount.
■
■
Shortly press on the TOTAL key.
■
■
Discharge begins.
The current flow rate is updated every 0.7 seconds. For this reason, the display may be relatively unstable
for low flow rates. The higher the flow rate, the higher the stability of the value indicated.
NOTE
The flow rate is measured in the measuring unit of the partial amount. If,
as in the following example, the partial amount and the total amount have
different measuring units, note that the flow rate shown is indicated in the
measuring unit of the partial amount. In the example below, the flow rate is
indicated in QTS./Min.