EN
07
4
、D/R
Adjustment range: 0-120%(the default is 100%), the step is 5%.
ST.D / R +: increase servo travel;
ST.D / R -: decrease servo travel.
ST
.D / R is for servo travel adjustment, which can be multiplexed as CH2 (throttle), CH3, CH4 servo travel
adjustment, see [5.5 Mode Switch] for multiplex switching mode;
LED Indicator:
When using the trim keys the G.LED will flash slowly on short presses and quickly on long presses.
When
t
he ra
tio
value
is a
t bot
h ends (0
/120%), t
he ST.D
/
R
button
is a
t
i
ts
ma
x
imum and as such G.LED
will
not fla
s
h (if the ratio value has been adjusted to 120%, then press ST.D/R+ key is invalid and G.LED
has Instructions)
5
、Mode switching
Mode 1: G.LED flashes slowly once, ST.TRIM is CH1 fine adjustment, ST.D / R is servo travel adjustment.
Mode 2: G.LED flashes twice slowly, ST.TRIM is CH1 fine adjustment, ST.D / R is CH2 servo travel adjustment.
Mode 3: G.LED flashes three times slowly, ST.TRIM is CH3 fine adjustment, ST.D / R is CH3 servo travel adjustment.
Mode 4: G.LED flashes slowly four times, ST.TRIM is CH4 fine adjustment, ST.D / R is CH4 servo travel adjustment.
This function is for reusing the ST.TRIM and ST.D / R buttons for different channels (see [5.3Trims], [5.4 D/R).
Function setting:
Under
normal po
w
er-o
n, qui
ckly p
ress
t
he Bind
button t
wice (w
it
hin 1 Sec)
to
cycle
thro
ugh
modes
1, 2,
3, and 4. The
default setting when powering on is mode 1.
Setup:
1. Turn on the transmitter and make sure it is connected to the receiver.
2. Hold the control surface at the desired failsafe position.
3. Press and
hold t
he
bind
button
f
or
3
second
s, i
f t
he G.LED
st
ar
t
s
fla
shing
every
2
seconds t
hen se
tup
has
been
successful.
-
6
、
Failsafe
This fun
ction
dic
t
a
t
es wha
t t
he
receiver
will
do
in
t
he
event t
ha
t
i
t loses
signal f
rom t
he
t
ransmi
tt
er
, t
his
includes
servo position etc.
Failsafe is now set and will default to these values when the receiver looses signal.
Setup:
To switch between beginner and normal modes press and hold the channel 4 button as the transmitter is turned on.
7
、Beginner Mode
Beginner
mode
is designed f
or
people
new
to
the
hobby.
In
this mode t
he
thrott
le will
be limited to
50 percent
,
The channel range defaults to 1250~1500~1750us.
N
ot
e
:
By defaul
t
,
t
he
system
is
set
to no
rmal m
od
e. The GLED will
fl
ash s
lowl
y f
o
r 3 sec
ond
s
during power on if the system is set to beginner mode.
N
ote:
The fail
-s
afe fun
ction ha
s
no d
efaul
t
se
t
at
t
he
facto
ry and as such mu
st b
e
set
manually.If
no
failsafe setting has been set, then the receiver will not output anything when signal is lost.