Operating Manual CMGZ432
16
9.2 Schematic diagram of main operating menu
fig. 12
C432010e
9.3 Checking the parameters
Before the initial setup is done, the following parameters have to be set resp. you have to
check if they correspond with the effective machine conditions (ref. to „11.
Parametrization“):
Measuring amplifier parameters
•
Nominal force
•
Unit of force
•
Sensitivity
•
1 or 2 sensors
PID controller parameters
•
Lowpass output
(reset to default)
•
Pilot control
(for the time being set to
None
)
•
PID-configuration
(for the time being set to
PI
; if PID configuration is required, refer
to „9.11 Additional Settings“)
•
Output limit
(set according to the drive used)
•
Output configuration
(set according to the drive used)
•
Ramp diameter
(reset to default)
•
Ramp reference
(reset to default)
•
Reference
(depending on machine configuration)
•
Scale ref. input
(if reference potentiometer is used)
•
Start speed
(for the time being set to 0.00)
•
Limit speed
(for the time being set to 0.0)