Operating Manual CMGZ432
35
Limit 1 min / max
Use:
The digital output „Limit value 1“ can be set as a min- or a max limit
switch. That means, that the digital output will be activated when passing
over resp. passing under the value set under parameter
Limit value 1
.
Range:
Min,
Max
Default:
Max
Limit value 1
Use:
The digital output „Limit value 1“ will be activated if the threshold
value stored in this parameter is passed over resp. under (according to
setting in parameter
Limit 1 min / max
).
Range:
-9999
to
9999
Default:
0
Increment:
1
Unit:
[N,kN]
Limit 2 min / max
Use:
The digital output „Limit value 2“ can be set as a min- or a max limit
switch. That means, that the digital output will be activated when passing
over resp. passing under the value set under parameter
Limit value 2
.
Range:
Min,
Max
Default:
Min
Limit value 2
Use:
The digital output „Limit value 2“ will be activated if the threshold
value stored in this parameter is passed over resp. under (according to
setting in parameter
Limit 2 min / max
).
Range:
-9999
to
9999
Default:
0
Increment:
1
Unit:
[N,kN]
Language
Use:
With this parameter, the language in the display can be chosen.
Range:
English, German, French, Italian
Pilot control
Use:
With this parameter, the operation mode of the pilot control is set.
Range:
No, Internal, External
Default:
No
Definition:
No:
No pilot control.
Internal: The line speed signal is evaluated; the reel diameter is
calculated
internally.
External: The diameter signal is evaluated; the reel diameter is
read from this external source.