www.fmiproducts.com
119303-01G
10
5. Slide other end of adjusting plate/shim
in slot on mitered edge of side trim (see
Figure 6).
6. While firmly holding edges of trim together,
tighten both set screws on the adjusting
plate with slotted screwdriver.
7. Repeat steps 1 through 6 for other side.
8. Tighten trim hanging screws (#10 x 6.25
shoulder) into holes in cabinets. Place
the assembled trim onto fireplace cabinet.
Align hanging notches on trim with hang-
ing screws on side of fireplace (see Figure
7). Push trim firmly into place, sliding
hanging notches over hanging screws.
INSTALLATION
Continued
INSTALLATION CLEARANCES
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling, and adjoining wall.
Carefully follow these instructions. This will
ensure safe installation.
*Minimum 16" from Side Wall
*
Example
Figure 8 - Minimum Clearance for
Combustible to Wall
Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 8.
Example:
The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This com-
bustible material must be 4" from the side
of the fireplace opening (see Figure 8).
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 42".
CONVENTIONAL FIREPLACE
INSTALLATION
Conventional installation of this fireplace
involves installing fireplace along with the
corner, face, or cabinet mantel with hearth
base accessories against a wall in your home.
Follow the instructions in this section to install
the fireplace in this manner.
1. Assemble cabinet mantel, hearth base,
and trim accessories. Assembly instruc-
tions are included with each accessory.
2. When installing blower, install a properly
grounded, 120 volt three-prong electrical
outlet at fireplace location if an outlet is not
there. If possible, locate outlet so cabinet
mantel will cover it when installed (see
Figure 9, page 11).
3. Install gas piping to fireplace location. This
installation includes an approved flexible
gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible
gas line must be the last item installed on
the gas piping. See
Installing Gas Piping
to Fireplace Location
,
page 13.
Figure 6 - Assembling Perimeter Trim
Side Trim
Slot
Mitered
Edge
Slot
Shim
Set Screws
Adjusting
Plate
Top
Trim
Mitered
Edge
Assembled
Trim
Figure 7 - Attaching Perimeter Trim to
Fireplace
Trim
Hanging
Screws
Hanging
Notches
on Trim