INSTALLATION
Continued
13"
16"
19"
21"
2
1
/
2
"
6"
8"
10"
Minimum Non-
Combustible
Material
Figure 16 - Minimum Mantel Clearances
for Built-In Installation
Mantel Shelf
Note:
All Vertical
measurements
are from top of
fireplace opening
to bottom of
mantel shelf.
IMPORTANT:
Noncombustible materials such
as brick, tile, etc. may overlap the front facing,
but should never cover any necessary open-
ings like louvered slots.
WARNING: Do not allow
noncombustible materials to
cover any necessary openings
like louvered slots.
WARNING: Use only non-
combustible mortar or adhe
-
sives when overlapping the front
facing with noncombustible
facing material.
Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace, you
must meet minimum clearance between man-
tel shelf and top of fireplace opening.
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• raise the mantel to an accept
-
able height
• remove the mantel
NOTICE: Surface temperatures
of adjacent walls and mantels
become hot during operation.
Walls and mantels above the
firebox may become hot to
the touch. If installed properly,
these temperatures meet the
requirement of the national
product standard. Follow all
minimum clearances shown in
this manual.
INSTALLING GAS PIPING TO
FIREPLACE LOCATION
WARNING: This appliance
requires a 1/2" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.
WARNING: A qualified service
person must connect fireplace
to gas supply. Follow all local
codes.
CAUTION: Never connect
propane/LP fireplace directly
to the propane/LP supply. This
fireplace requires an external
regulator (not supplied). Install
the external regulator between
the fireplace and propane/LP
supply.
WARNING: Never connect
natural gas fireplace to private
(non-utility) gas wells. This
gas is commonly known as
wellhead gas.