www.fmiproducts.com
112301-01E
15
(V)GL36CR, (V)GL36CRE, (V)GL36CL, (V)
GL36CLE
• Maximum Input Rating at Altitudes: 0-2,000
ft. - 42,000 Btu/hr., 2,000-4,000 ft. - 37,800 Btu/
hr.
• Manifold Pressure: 3.5 W.C. (.87 kPa)
• Supply Pressure (in. of water): Minimum* - 4.5"
(1.12 kPa), Maximum - 11.0" (2.74 kPa)
• Orifice Size at Altitudes: 0-2,000 ft. - #30,
2,000-4,000 ft. - #31
(V)GL36CRP, (V)GL36CRPE, (V)GL36CLP,
(V)GL36CLPE
• Maximum Input Rating at Altitudes: 0-2,000
ft. - 42,000 Btu/hr., 2,000-4,000 ft. - 37,800 Btu/
hr.
• Manifold Pressure: 11.0 W.C. (2.74 kPa)
• Supply Pressure (in. of water): Minimum* -
12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)
• Orifice Size at Altitudes: 0-2,000 ft. - #49,
2,000-4,000 ft. - #51
* For the purpose of input adjustment
DO NOT
CONNECT
N.C.SW
HEAT LIMIT SWITCH
TH/TP
TP
TH
WALL SWITCH
(SUPPLIED)
TO 120V
THERMOPILE
PILOT
IGNITOR
O
F
F
P I
L
O
T
ON
PILOT SAFETY WIRE
MAIN GAS
INCOMING
SUPPLY
MILLIVOLT WIrING DIAGrAM
ELECTrONIC WIrING DIAGrAM
WIRING DIAGRAMS
STEP DOWN
TRANSFORMER
EV2
SUPPLY
INCOMING
MAIN GAS
EV1
TO
GAS LINE
BURNER
24V AC
N.C.SW
HEAT LIMIT
SWITCH
120V AC
120V AC
INCOMING
OR BREAKER)
(FUSE BOX
OFF
ON
(SUPPLIED)
USE ONLY CL2 THRMST WIRE
18 GA. RED/WHT (PROVIDED)
OR EQUIVALENT
WALL SWITCH
GREEN
BLACK
WIREW
A
Y
WHITE
120v, 60Hz, 0.7A
ELECTRICAL RATING:
BLACK
CONNECTORS
(NOT SUPPLIED)
FIELD WIRE
WHITE
GREEN
OPTIONAL
REMOTE
CONTROL
SENSOR
PILOT
IGNITOR
P
V
G
N
D
PV
/M
V T
R
M
V
TH
IG
N
SPECIFICATIONS