www.fmiproducts.com
112301-01E
11
OPERATING FIREPLACE
MILLIVOLT MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per
-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t
try to repair it. Call a qualified service tech-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Turn wall switch to the OFF position.
3. Turn off all electric power to the appliance.
4. Open control access panel.
5. Push in gas control knob and turn clock-
wise
to the OFF position (see
Figure 19).
Note:
It is recommended that
you maintain the gas control knob in the
full OFF position during lengthy periods
of seasonal non usage.
6. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information in column 1. If you don’t
smell gas, go to the next step.
7. Turn control knob counterclockwise
to the PILOT position.
8. Push in control knob all the way and hold
in. Immediately light the pilot by pressing
the red ignitor button until a flame ap-
pears. Continue to hold the control knob
in for about (1) minute after the pilot is lit.
Release knob and it will pop back up. Pilot
should remain lit. If it goes out, repeat steps
5 through 7. The pilot is located by main
burner (see Figure 20).
• If knob does not pop up when released,
stop and immediately call your service
technician or gas supplier.
• If the pilot will not stay lit after several
tries, turn the gas control knob to OFF
and call your service technician or gas
supplier.
9. Turn gas control knob counterclockwise
to ON. Knob can be turned to ON
only if the control knob is popped out.
10. Replace control access panel.
11. Turn on all electric power to the appliance.
Figure 19 - Millivolt Control Valve
Position Indicator
Gas Control Knob
Figure 20 - Pilot
Thermopile
Pilot
Burner
Ignitor