14
CAST IRON STOVE AND BURNER SYSTEM
107599
For more information, visit www.desatech.com
VENTING
INSTALLATION
Continued
Figure 31 - Horizontal Termination
Configuration for Rigid Venting Using
One 90
°
Elbow
Horizontal Venting
Vertical (V)
Horizontal (H)
55" min.
24" max.
66" min.
46" max.
88" min.
20' max.
Note: This configuration for use with
corner installation.
Horizontal Termination
Configurations
Figures 31 through 33 show different con-
figurations for venting with horizontal ter-
mination. Each figure includes a chart with
vertical minimum/maximum and horizon-
tal maximum dimensions which must be
met. Seal all connections with high tem-
perature silicone sealant (outer pipe only) as
specified in the second warning statement
on page 11. All horizontal terminations re-
quire 1/4" rise per 12" of horizontal run.
UP
Venting with Two 90
°
Elbows
Vertical (V)
Horizontal (H
1
)
Horizontal (H
1
) +
Horizontal (H
2
)
6' min.
4' max.
8' max.
7' min.
6' max.
12' max.
8' min.
8' min.
20' max.
20' max.
8' max.
20' max.
Figure 32 - Horizontal Termination Configuration for Rigid Venting Using Two
90
°
Elbows
Venting with Two 90
°
Elbows
Vertical (V)
Horizontal (H
1
) +
Horizontal (H
2
)
6' min.
4' max.
7' min.
6' max.
8' min.
10' max.
20' max.
12' max.
Figure 33 - Horizontal Termination Configuration for Rigid Venting Using Two 90
°
Elbows with Termination at 90
°
with Stove
UP
*
Note: Add 1/4" rise per 12"
horizontal length of pipe.
*
*
*
*
Note: Add 1/4" rise per 12"
horizontal length of pipe.
*
Note: Add 1/4" rise per 12"
horizontal length of pipe.