27
107599
OWNER’S MANUAL
For more information, visit www.desatech.com
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the
proper flame height. Alterations may have
occurred during shipping and handling. Call
a qualified service person to readjust the
pilot if necessary.
The height of the thermopile must be 3/8" to
1/2" above the pilot flame as shown in Figure
65. The thermocouple must be at a height of
about 1/8" above the pilot flame. The flame
from the pilot burner must extend beyond
both the thermocouple and thermopile.
If your pilot assembly does not meet these
requirements:
• turn burner system off (see To Turn Off
Gas to Appliance, page 25)
• see Troubleshooting, pages 29 through 31
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or
floating. Flame patterns will be different
from unit to unit and will vary depending on
installation type and weather conditions.
If the vent configuration is installed incor-
rectly, the flames will lift or “ghost”. This
can be dangerous. Inspect the flames after
installation to ensure proper installation and
performance.
Figure 66 shows a typical flame pattern. If
burner flame pattern differs from that
described:
• turn burner system off (see To Turn Off
Gas to Appliance, page 25)
• see Troubleshooting, pages 29 through 31
Figure 66 - Typical Flame Pattern
OPERATING STOVE
WITH BURNER
SYSTEM
Continued
OPERATING
OPTIONAL BLOWER
ACCESSORY
Locate the blower controls on right side of
rear cover (standing in front of stove).
The DA3610TA thermostatically-con-
trolled blower has an ON setting and an
OFF setting. The blower will only run when
the switch is in the ON position. In the OFF
position, the blower will not operate.
If you are using DA3610TA blower with
optional thermostat (wall mount or re-
mote control) for the burner system, your
burner system and blower will not turn on
and off at the same time. The burner
system may run for several minutes before
the blower turns on. After the burner
system modulates to the pilot position, the
blower will continue to run. The blower
will shut off after the burner system tem-
perature decreases.
The blower helps distribute heated air
from the burner system. Periodically check
the air passageways of the burner system
and remove any dust, dirt, or other ob-
structions that will hinder the flow of air.
OPERATING
OPTIONAL GWMT1
WALL MOUNTED
THERMOSTAT
Light the burner system as instructed in
Lighting Instructions on page 25. Set wall
thermostat to desired temperature.
This thermostat has been electronically
calibrated at the factory and requires no
adjustment or leveling.
WARNING: Do not connect
the thermostat to a power source.
Electrical shock and/or a fire haz-
ard will occur.
Upon installation, the thermostat must
be allowed to stabilize at room tempera-
ture for a minimum of 30 minutes for
proper operation.
To turn the burner system off, adjust
thermostat to the lowest setting and turn
the gas control knob back to PILOT. The
pilot will remain lit.
IMPORTANT:
To turn the pilot off, turn
the gas control knob on the burner sys-
tem to the OFF position.
Figure 65 - Pilot Assembly
Thermopile
Pilot Burner
Thermocouple
Piezo Ignitor
1/8"
3/8" to 1/2"