www.fmiproducts.com
125024-01A
23
OPERATION
Continued
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to the
OFF position.
2a. Set switch in the OFF position.
2b.
If Using Optional Hand-Held Remote:
Set selector switch in the OFF position to
prevent draining battery.
3. Close equipment shutoff valve (see Figure
15, page 15).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under
Lighting
Instructions
, page 21.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30 sec-
onds, release control knob. Now follow
steps 9 through 11,
Lighting Instructions
,
page 22.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must
be purchased separately (see Accessories,
page 34). Follow instructions included with
the remote control.
NOTICE: You must light the pilot
before using the hand-held re
-
mote control unit. See
Lighting
Instructions
on page 21.
After lighting, let pilot flame burn for about
one minute. Turn control knob to ON position.
Adjust flame adjustment knob anywhere be
-
tween HI and LO. Slide the selector switch to
the REMOTE position (see Figure 32).
Figure 32 - Control Knob, Ignitor Button
and Remote Selector Switch
Selector
Switch
Control
Knob in OFF
Position
Flame
Adjustment
Knob
Ignitor
Figure 33 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 34 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 33 shows a correct pilot flame pattern.
Figure 34 shows an incorrect pilot flame pat
-
tern. The incorrect pilot flame is not touching
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools,
the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 34
• turn heater off (see
To Turn Off Gas to Ap-
pliance
, page 23
• see
Troubleshooting
, page 26
Note: The pilot flame on natural gas units will
have a slight curve, but flame should be blue
and have no yellow or orange color.
INSPECTING bURNERS
Note: The burner may light if hand-held re-
mote was on when selector switch was last
turned off. You can now turn burner on and off
with hand-held remote control unit.
IMPORTANT:
Do not leave selector switch in
the REMOTE or ON position when pilot is not
lit. This will drain the battery.
Note: Do not hold hand-held remote for a long
time. Body temperature will affect its operation
in the AUTO mode.
f i r e - p a r t s . c o m