www.fmiproducts.com
125079-01F
25
MAIN
IN
OUT
PILOT
ADJ
PILOT
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per
-
sonal injury or loss of life.
A. This appliance is equipped with an igni
-
tion device which automatically lights
the pilot. Do not light pilot by hand.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
C. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also
be present. Open damper or
window to vent smell. This will
only last a few hours.
Figure 34 - Turning Equipment Shutoff Valve to the OFF Position
Equipment
Shutoff Valve
1. STOP! Read the safety information in
column 1.
2. Turn off all electric power to fireplace.
3. Turn safety shutoff switch to the OFF
position.
4. Remove center brick/control cover.
5. Turn equipment shutoff valve clockwise
to the OFF position (see Figure
34). Do not force.
6. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information page 24. If you
don't smell gas, go to the next step.
7. Turn equipment shutoff valve counter
-
clockwise
to the ON position. Do
not force.
8. Replace center brick/control cover.
9. Turn on all electric power to appliance.
10. Turn safety shutoff switch to the ON
position.
11. Visually locate pilot. Ignitor should begin
to spark and main burner should ignite
once flame appears at pilot.
• If lighting appliance for the first time each
season, it may take several attempts
before supply gas can reach pilot and
main burners.
• If appliance will not stay lit after several
attempts, follow instructions under
To
Turn Off Gas To Appliance
and call your
service technician or gas supplier.
TO TURN OFF GAS
TO APPLIANCE
1. Turn off safety shutoff switch.
2. Turn off all electric power to appliance if
service is to be performed.
3. Remove center brick/control cover.
4. Turn equipment shutoff valve clockwise
to OFF. Do not force.
5. Replace center brick/control cover.
Incoming
Gas Line