www.fmiproducts.com
125079-01F
26
GAS CONTROL MODULE SYSTEM
The module has 2 special features built into
the system.
CONTINUOUS PILOT FEATURE
This allows the change from a spark to pilot
system to a standing pilot system
1. There is a switch located on the right side
of the module that reads CONTINUOUS
PILOT ON/OFF. This switch selects the
pilot's mode of operation (Figure 35).
2. When the continuous pilot switch is in the OFF
position and the appliance rocker switch
is turned ON, the pilot will spark and light.
When the appliance rocker switch is turned
OFF, the pilot will shut OFF when the main
burner shuts OFF.
3. When the continuous pilot switch is in the ON
position and the appliance rocker switch
is turned ON, the pilot will spark and light.
When the appliance rocker switch is turned
OFF, the pilot will stay ON when the main
burner shuts OFF.
4. The continuous pilot mode can also be acti
-
vated by the Remote Control.
REMOTE CONTROL FEATURE
The module has a built in remote control
receiver that allows the user to
program the remote transmitter at any
time during or after the installation of
the burner.
Continuous Pilot
Off/On Switch
Remote/Off Switch
ADJ.
“S” Pilot Connection
“I” Pilot Connection
AF-4000 MOD Module Rt Side
Figure 35 - Gas Module Right Side
1. There is a switch located on the right side
of the module that reads REMOTE/OFF
(Figure 36).
2. When the remote/off switch is in the OFF
position, the burner will operate from the
rocker switch or wall switch connected to
the two BROWN wires on the module.
3. When the remote/off is in the REMOTE
position the burner will operate from the
Remote Control transmitter.
NOTE: The module must be programmed to
the Remote Control transmitter.
• To program the module (make sure the
system has power), locate the learn
button (Figure 36) on the module. Press
and release the learn button. There will
be a beep sound from the module. Then
press any button on the remote transmit
-
ter. Once the module's internal receiver
accepts the transmitter code, there will
be a series of confirming beeps.
• The remote system is ready for use.
AF-4000 MOD Module Lt Side
AUX Connection
Learn Button
Figure 36 - Gas Module Left Side
BATTERY BACK-UP
This fireplace is equipped with a battery back-
up. If the power was to go out on the fireplace,
the battery back-up allows the fireplace to
remain operational. Make sure to periodically
check the condition of the four AA batteries
used for the battery back-up.