FIREPLACE INSTALLATION
Continued
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas valve (see Figure 25 or
Figure 26, page 20). Apply noncorrosive
leak detection fluid to all joints. Bubbles
forming show a leak. Correct all leaks at
once.
5. Light fireplace (see
Operation
, page 25).
Check all other internal joints for leaks.
6. Turn off fireplace (see
To Turn Off Gas to
Appliance
, page 25).
REMOVING/REPLACING GLASS
DOOR
Figure 27 - Removing/Replacing Door
Removing Glass Door
If replacement of glass is necessary, the entire
frame assembly must be replaced. Gloves
must be worn when removing/replacing glass
door. If glass is broken tape remaining glass
onto frame before removing.
1. Remove screens if installed.
2. Open bottom access panel.
3. Unlock 2 door latches on bottom of
firebox.
4. Tilt open glass door 45° from the bottom
of firebox and lift up to release door from
firebox top retainer (see Figure 27).
Replacing Glass Door
1. Position door frame in front of firebox
opening with bottom of door tilted away
from firebox (see Figure 27).
2. Hook top flange of door frame over top of
firebox frame.
3. Secure 2 bottom door latches.
Door
Retainer
Glass
Door
Bottom
Access Panel
Door
Latches
CAUTION: Do not operate
this fireplace with a broken glass
door panel or without the glass
door panel securely in place. For
replacement part information
see
Replacement Parts
, page 33.
CAUTION: Wear gloves and
safety glasses while handling
or removing broken glass.
Do not remove if glass is hot.
Keep children and pets away
from glass.
WARNING: If fireplace has
been running, turn off fireplace.
Let cool before removing glass
doors.