background image

 

Slimfire 25 Zero Clearance Box  

 

10/06/2003 

1

RINNAI SLIMFIRE Zero Clearance Kit 

If the heater is to be installed into a combustible opening, 

the Rinnai Zero Clearance Kit ZEROS must be used. 

 
 

Parts included in the Zero Clearance kit are: 
 
1 Top panel 
1 Base panel 
2 Side panels 
1 Rear panel 
1 Flue adaptor 
2 Base support runners 
1 Plinth 
1 pkt screws 
1 Slip Socket

 

685 mm

675 mm

370 mm

 

Build frame as set out in (Fig.1). 
 
Lay the base panel on the floor with return fold upward. 
 
Stand side panels on the outside of the base panel 
with the securing fold to the front as shown in (fig.2). 
 
Slide rear panel between side panels, ensuring that the 
gas inlet hole is in the bottom right-hand corner. 
 
 

 
 

 

Place the top panel with the return fold forward, with 
the flue outlet to the rear. 
 
The Zero Clearance Box should now be stable enough 
on its own to secure the self-tapping screws in the 
holes provided. (Fig. 3) 
 
Run the gas line to the appropriate position. 
 
The Zero Clearance Box can now be secured to the 
framing using the holes provided. 
 
 

 

Securely connect the flue adaptor to the rear of the 
slimfire heater (Fig.4). 
 

 

Rear Panel

Top Panel

L/H Side Panel

R/H Side Panel

Base Support Runners

Plinth

Base Panel

Fig.1

Fig.3

Fig.4

Fig.2