www.fmiproducts.com
126116-01D
15
ELECTRICAL HOOKUP AND
REMOTE RECEIVER DIAGRAM
An outlet box with two receptacles (see Figure
18) has been supplied for your convenience
and is located inside on the lower right side of
the fireplace.
Figure 18 - Duplex Outlet
Three-prong Plug
Outlet Box
INSTALLATION
Continued
Vertical (V) Horizontal (H)
5' min.
2' max.
6' min.
4' max.
7' min.
6' max.
8' min.
8' max.
20' max.
8' max.
Figure 15 - Vertical Venting Configuration
Using One 90° Elbow (Vertical Round
High Wind Termination Shown)
Note: Install restrictor
into inner collar of
fireplace as shown.
Vertical
(V
1
)
Horizontal
(H)
5' min.
6' max.
6' min.
12' max.
7' min.
18' max.
8' min.
20' max.
Note
: Vertical (V
1
) +
Vertical (V
2
) = 40’ max.
Figure 16 - Vertical Venting Configuration
Using Two 90° Elbows (Vertical Round
High Wind Termination Shown)
Note: Install restrictor
into inner collar of
fireplace as shown.
45° Elbow
45° Elbow
Venting with Two
90° Elbows
Venting with One 90° Elbow
Vertical Venting
V = 40’ max.
Figure 17 - Vertical Venting Configuration
With No Horizontal Run (Vertical Round
High Wind Termination Shown)
Note: Install restrictor
into inner collar of
fireplace as shown.
45° Elbow