www.fmiproducts.com
126116-01D
12
Vertical (V) Horizontal (H) Series
32
3
/
4
" min.
17" max.
CD36
Horizontal High
Wind Square
Termination
Wall
Firestop
45° Elbow
Adjustable Pipe
12" Max.
Square Termination
INSTALLATION
Continued
Figure 9 - Horizontal Termination
Configuration for Square and Round
Terminations
45° Elbow
Wall
Firestop
Round
Termination
Cap
Exterior Portion of
Wall Firestop (Round
Termination Only)
Round Termination
Slide Ring
Over Elbow
to Complete
Connection
Vertical (V) Minimum
Required Vertical Pipe
Horizontal (H) Maximum
*
43
1
/
2
" None 30"
54
1
/
2
"
1 ft.
48"
66
1
/
2
"
2 ft.
60"
78
1
/
2
"
3 ft.
84"
90
1
/
2
"
4 ft.
20'
Figure 10 - Horizontal Termination
Configuration for Corner Installation
Using One 90° Elbow
Square
Termination
Wall
Firestop
Not to Exceed
(H) Limits
As Required
for (V)
See Chart
for Pipe
Section
Required
45°
Elbow
90° Elbow
90° Elbow
Square
Termination
Wall
Firestop
45° Elbow
12"
Minimum
*Note: Ground Floor Corner Venting
Not to Exceed
(H) Limits
TYPICAL CORNER INSTALLATION
Recommended Applications:
• Corner ground floor installation
• Ground floor installation where pipe vents
horizontally through wall (over 12" horizon-
tal pipe)
• Basement installation where one foot
clearance from ground to termination is
possible