FLYGT MP-3102 & 3127 PUMP
Safety Precautions
Before starting work on the pump, make sure that the pump is isolated from the power supply and cannot be
energized.
NOTE! This applies to the control circuit as well.
The following points are important in connection with work on the pump:
-
Make sure the pump has been thoroughly cleaned.
-
Observe good personal hygiene.
-
Beware the risk of infection.
-
Follow local safety regulations.
The pump is designed for use in liquids which can be hazardous to health. In order to prevent injury to the eyes and
skin, observe the following points when working on the pump:
-
Always wear goggles and rubber gloves.
-
Rinse the pump thoroughly with clean water before starting work.
-
Rinse the components in water after disassembly.
-
The oil housing may be under pressure. Hold a rag over the oil casing screw (oil plug) and the
inspection screw to prevent splatter.
Proceed as follows if you get hazardous chemicals in your eyes:
-
Rinse immediately in running water for 15 minutes. Hold your eyelids apart with your fingers.
-
Contact an eye specialist.
On your skin:
-
Remove contaminated clothes.
-
Wash your skin with soap and water.
-
Seek medical attention, if required.
Inspection
Regular inspection and preventive maintenance ensure more reliable operation.
The pump should be inspected after 2000 hours of operation or at least once a year, more frequently under sever
operation conditions.
Under normal operating conditions, the pump should have a major overhaul in a service shop after 6000 hours of
operation or every three years.
When the pump is new or when the seals have been replaced, inspections are recommended after one week of
operation.
Recommended Inspections
Inspection of
Action
Visible parts on pump
Replace or fix worn and damaged parts.
And installation
Make sure that all screws, bolts and nuts are tight.
Check the condition of carrying handle/lifting eyes, chains and wire ropes.
Check that the guide bars are vertical.
Pump casing and impeller
Replace worn parts if they impair function.
If the clearance between the impeller skirt and the pump casing exceeds
0.08 in, see “Replacing the wear ring”.