2. Tighten the M24 nuts.
Tightening torque: 629 Nm (464 ft-lbs).
M24
586 02 00
Storage guidelines
Storage location
The product must be stored in a covered and dry location free from heat, dirt, and vibrations.
NOTICE:
• Protect the product against humidity, heat sources, and mechanical damage.
• Do not place heavy weights on the packed product.
Freezing precautions
The pump is frost-proof while operating or immersed in liquid, but the impeller/propeller and the shaft
seal may freeze if the pump is lifted out of the liquid into a surrounding temperature below freezing.
Follow these guidelines to avoid freezing damage:
When
Guideline
Before storage
• The pump must be allowed to run for a short time after raising it
to discharge remaining pumped liquid.
This does not apply to propeller pumps.
• The discharge opening must be covered in a suitable way, or
placed facing down so that any still remaining pumped liquid runs
out.
• If present, the cooling jacket must be drained manually by
opening the air vent screws at the top of the cooling jacket.
Transportation and Storage
18
C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual