No.
Menu name
Specification
Description
8_9
Overflow segment 4
GPM
WritableCentral System
TextOverflow segment 4 (GPM)
Overflow segment 4 used by the manual calculation method to
calculate overflow flow and overflow volume.
8_10
Overflow segment 5
GPM
WritableCentral System
TextOverflow segment 5 (GPM)
Overflow segment 5 used by the manual calculation method to
calculate overflow flow and overflow volume.
8_11
Overflow segment 6
GPM
WritableCentral System
TextOverflow segment 6 (GPM)
Overflow segment 6 used by the manual calculation method to
calculate overflow flow and overflow volume.
8_12
Overflow segment 7
GPM
WritableCentral System
TextOverflow segment 7 (GPM)
Overflow segment 7 used by the manual calculation method to
calculate overflow flow and overflow volume.
8_13
Overflow segment 8
GPM
WritableCentral System
TextOverflow segment 8 (GPM)
Overflow segment 8 used by the manual calculation method to
calculate overflow flow and overflow volume.
8_14
Overflow segment 9
GPM
WritableCentral System
TextOverflow segment 9 (GPM)
Overflow segment 9 used by the manual calculation method to
calculate overflow flow and overflow volume.
8_15
Overflow segment 10
GPM
WritableCentral System
TextOverflow segment 10 (GPM)
Overflow segment 10 used by the manual calculation method to
calculate overflow flow and overflow volume.
8_16
Overflow flow GPM
Read only
Overflow flow
8_17
Overflow volume gal Read only
Overflow volume
8_18
Overflow count
Writable
Number of overflows.
8_19
No. of major overfl.
Writable
No. of major overfl.
8_20
Overflow time h:min Writable
Overflow time.
9
Rain inch
Writable
Rain daily value.
9_1
Rain alarm 5min
inch/5min
Writable
Rain limit for 5 minute period.
9_2
Rain alarm 24h
inch/24h
Writable
Rain alarm limit for 24 hours.
9_3
Rain scale inch/pulse Writable
Rain meter scale factor.
10
Flows and volumes
Read only
Flows and volumes
10_1
Free flowGPM
Read only
Free flow
10_2
Pumped volume gal Read only
Pumped volume
10_3
Sump volume gal
Read only
Sump volume
11
Sump form
Read only
Sump form
11_1
Area ft2
WritableCentral System TextArea
(ft2)
This is the area that is used in the capacity calculations.
12
Capacity
Read only
Capacity
12_1
Calc. capacity P1GPM Read only
Calc. capacity P1
12_1_1 Nominal capacity
P1GPM
WritableCentral System
TextNominal capacity P1 (GPM)
Enter the nominal capacity of P1. Used for capacity alarms.
12_1_2 Capacity div. P1GPM WritableCentral System
TextCapacity divergation limit P1
(GPM)
Divergation limit for high and low capacity alarms. Uses nominal
ca/- this channel.
Appendix A: RTU Descriptions
50
APP 541 User manual