![Flux FLUXTRONIC Original Attachment Download Page 55](http://html1.mh-extra.com/html/flux/fluxtronic/fluxtronic_original-attachment_2310932055.webp)
Attachment FLUXTRONIC Automatic Mode
55 / 84
ENGLI
SH
When the battery capacity is almost empty, the information line shows
"LOW BATT" alternatively with the current line. When this is the case, the
electronic unit can run normally for up to 2 weeks.
When the battery capacity is so low that processing can no longer be reliably guaran-
teed, the display only shows "LOW BATT" and the functions are no longer operated.
6
Commissioning
Attention!
If the material of the flowmeter is not resistant to the liquid
to be transferred, it must not be used.
Observe the chemical resistance and internal operating
instructions.
Note!
Check if the materials of the flow meter are appropriate for the
applications.
Note!
Generally replace a defect signalling cable.
7
In operation
Regularly check the flow meter for function.
8
Repair
Warning!
When non-approved spare-parts are used persons can be hurt and
the machine/equipment can be damaged.
Only use spare and wear parts that are approved by the manufactur-
er.
> Depressurise the system.
> Separate pump from current.
> Empty hose, flowmeter and valves.
> Always replace defective parts.
> Only use genuine spare parts .
Summary of Contents for FLUXTRONIC