12
VIBRONET Installation 06.2016
Technical data
VIBRONET MUX - VIB 8.306..
Limited temperature range
The lower temperature limit (-40 ° C) applies only if the sensor cable
is connected directly to the multiplexer. When using connection mod-
ules the lower temperature limit is -20 ° C.
PARAMETER
VIB 8.306
VIB 8.306 M20
VIB 8.306-V M20
General
Housing material
Cast aluminum housing, powder coated
Stainless steel (VA)
Inputs / Outputs
9 sensor inputs, 1 string input, 1 string output
Env. protection
IP 65
IP 66
Temperature range
-40C° ...+ 80°C
Clamping range M12
3.0 ... 6.5 mm
--
-, M20
7.0 ... 12.0 mm
Dimensions LxWxD
224 x 120 x 98 mm
253 x 253 x 120 mm
Weight
approx. 3 kg
approx. 5 kg
Electrical
Power supply
Approx. 10 V from VIBRONET Signalmaster ‘string’ output
Current consumption
In µA range
Interference protect.
Inputs and outputs protected by suppressor diodes
PARAMETER
VIB 8.306 EX
VIB 8.306-V EX M20
General
Housing material
Cast aluminum housing, powder coated
Stainless steel (VA)
Inputs / Outputs
9 sensor inputs, 1 string input, 1 string output
Env. protection
IP 65
IP 66
Temperature range
-40C° ...+ 70°C
Clamping range M12
3.0 ... 6.5 mm
--
-, M20
7.0 ... 12.0 mm
Dimensions LxWxD
224 x 120 x 98 mm
253 x 253 x 120 mm
Weight
approx. 3 kg
approx. 5 kg
Electrical
Power supply
approx. 10 V, from VIBRONET Signalmaster ‘string’ output
Current consumption
In µA range
Interference protect.
Inputs and outputs protected by suppressor diodes
EX
Marking
II 2 G Ex ib [ib] IIC T4
Electrical parameters
The relevant electrical parameters with regards to intrinsic safety are
given in section 5.2 (see 'Conditions for the safe operation (MUXes
and sensors):', page 47).