
13
Workgroup Analyzer
Configuring the Analyzer through the Serial Configuration Port
Root mode user commands:
Remote mode user commands
“management”
Allows the user to enter “Management” configuration mode.
This mode allows the user to configure IP parameters for the
out-of-band Management Port. The text “/Management>” is
appended to the prompt while in this mode.
“network”
Allows the user to enter “Network” configuration mode. This
mode allows the user to configure IP parameters for the in-band
10/100/1000/Fiber ports. The text “/Network>” is appended to
the prompt while in this mode.
“default”
Restores the analyzer configuration parameters back to factory
defaults and reboots the analyzer. Password settings are
retained.
“productinfo”
Displays analyzer product information.
“exit”
Exits the Root mode if password protection is enabled. The user
must enter the correct password to regain configuration access.
“show (user command)”
Displays the current value of an individual setup parameter of
interest within the Root mode.
“show all”
Displays the current values of all setup parameters within the
Root mode.
“remoteipaddr A.B.C.D |last connected | none”
Sets the IP address (A.B.C.D) of the PC that will be running the
remote user interface software. The analyzer will send it’s
identification to that PC so that the OptiView Browser will
display that analyzer for selection. The address is entered in
decimal dot notation. See help for more information about
setting the Remote PC IP address.
“import1ipaddr A.B.C.D | none”
and
“import2ipaddr A.B.C.D | none”
Sets the IP address (A.B.C.D) of up to two PCs that are running
software that will import data from the analyzer such as
OptiView Reporter or OptiView Console. The analyzer will then
send it’s identification to that PC so that the import software can
use the analyzer as a data source, receive the problem log from
the analyzer, and display the analyzer as an agent. See help for
more information about setting the Remote PC IP address.
“syslog1ipaddr A.B.C.D | none”
and
“syslog2ipaddr A.B.C.D | none”
Sets the IP address (A.B.C.D) of up to two PCs that will receive
information about packet captures called a syslog server (also
referred to as syslog collector). See help for more information
about setting the syslog server IP address.
“exit”
Exits to the Root mode. Changes are saved.
“show (user command)”
Displays the current value of a Remote mode individual setup
parameter.
“show all”
Displays the current values of all setup parameters within the
Remote mode.
Summary of Contents for OptiView III Series
Page 4: ......
Page 29: ...23 Workgroup Analyzer Safety and General Specifications...
Page 33: ......