11
Workgroup Analyzer
Accessing the Analyzer through the Remote User Interface Software
User Interface Events that will Terminate a Remote Session
The active TCP/IP session between the user interface software and the analyzer can be severed under the
following conditions:
IP parameters are manually changed on the analyzer and Apply is selected in the Management port TCP/
IP setup screen
Note
The following conditions only apply to the Network 10/100/1000 and 1000BASE-X
fiber ports, and not to the Management port.
Auto Reconfigure on Network Change
is checked in the TCP/IP setup screen and the analyzer patch
cable is disconnected and reconnected to another jack
The Ethernet link goes down on either interface due to temporary network outage
Rerun Auto Configure
is selected in the TCP/IP setup screen
Find Unused IP and Apply
is selected in the TCP/IP setup screen
IP parameters are manually changed and
Apply
is selected in the TCP/IP setup screen
Rerun Cable Test
is selected
If the Analyzer MAC address is changed in the
Setup | Ethernet
screen
If
Receive only, do not transmit frames
is selected in the
Setup | Ethernet
screen
Summary of Contents for OptiView III Series
Page 4: ......
Page 29: ...23 Workgroup Analyzer Safety and General Specifications...
Page 33: ......