CONFIGURATION EXAMPLES INTRINSICALLY SAFE APPLICATIONS:
Configuration example no. 1
*Sensor supply voltage for pulse tachometer type P : Terminal 3: 1.2
- 3.2V DC.
Please note: type PX may be used in combination with the battery (type PC).
PX will power the unit; the battery will be disabled automatically till power is disconnected.
HAZARDOUS AREA
SAFE AREA
I.S. tachometer
input type: P
pulse
Configuration example IIA - IIB and IIC
battery powered unit
F093-P-(OT)-PC-(PX)-XI-(ZB) -
Basic power supply type PX:
8-30V DC
(not used in this example).
Alarm output type OT:
passive transistor
(not used in this example).
Backlight option: type ZB
(not used in this example).
TERMINAL CONNECTORS
F0-series
1
3
Common ground
Signal
Supply *
7
8
Common ground
Common ground
Main supply
9
1
0
Common ground
Supply backlight
C
irc
u
it
de
pe
n
ds
o
n
ty
p
e
o
f s
ig
n
al
2
4
5
Fig. 15: Configuration example Intrinsically Safe.
Configuration example no. 2
Configuration example IIA - IIB and IIC application - F093-P-OT-PX-XI-(ZB)
I.S. tachometer
input type: P
pulse
Backlight option: type ZB
(not used in this example).
TERMINAL CONNECTORS
F0-series
Common ground
Signal
Supply *
Common ground
Common ground
Main supply
Common ground
Supply backlight
HAZARDOUS AREA
SAFE AREA
+
-
Power supply
For example
MTL5025
+
-
Power supply or
switch interface
For example
MTL5025
MTL5011B
= max. 30 V
= max. 200 mA
= max. 1,2 W
Uo
Io
Po
= max. 30 V
= max. 200 mA
= max. 1,2 W
Uo
Io
Po
Note: above values are safety values.
Consult the technical specification for operational values.
Power supply type PX: 8-30V DC
*Sensor supply voltage for pulse type P: Terminal 3: 1.2V - 3.2V DC.
Please note: type PX may be used in combination with the battery (type PC). PX will power the unit; the battery will be disabled automatically till power is disconnected.
e.g. sounder
Alarm output type OT: passive transistor
Intrinsically Safe apparatus
10
9
8
7
5
4
3
2
1
C
irc
ui
t d
e
pe
nd
s
o
n
ty
pe
o
f
si
gn
al
Fig. 16: Configuration example Intrinsically Safe.