SENSOR SUPPLY
Type PF-PM: Sensor supply: 1.2, 3.2V, 8.2V, 12V or 24 V:
With this option, a real power supply for the sensor is available. The Tachometer can be powered
with 1.2, 3.2, 8.2, 12 or 24 V DC (max. 400mA@24V). The voltage is selected with the three
switches inside the enclosure.
Warning: be sure that all the leads to the terminals are disconnected from the unit when
the internal plastic protection cover has been removed !
HIGH VOLTAGE 400V !! NEVER connect the mains power supply to the unit when the
plastic protection cover has been removed !!!
First, remove the terminal strip(s) after which the internal plastic cover can be removed. The
switches are located on the right hand side as indicated:
Fig. 11: switch position voltage selection (type PF and PM).
Switch positions / sensor supply voltage:
VOLTAGE SELECTION
SWITCH
1.2
/
3.2V
DC 8.2V
DC 12V
DC 24V
DC
J1
on
off
off
off
J2
on or off
on
on
off
J3
on or off
on
off
on or off
REMARKS: TERMINAL CONNECTORS:
Terminal GND- 01- 02; POWER SUPPLY only available with type PF / PM:
O
PTION
SENSOR SUPPLY
T
erminal
GND
01
02
PF
24V AC
±
10%
1.2, 3.2, 8.2, 12, 24V max. 400mA@24V DC
AC AC
PF
24V DC
±
10%
1.2, 3.2, 8.2, 12, 24V max. 400mA@24V DC
L-
L+
PM
115-230V AC
±
10% 1.2, 3.2, 8.2, 12, 24V max. 400mA@24V DC EARTH
AC
AC
Note PF / PM The running hours consumption of the sensor, transistor output type OA and
backlight type ZB may not exceed 400mA@24V DC.
J3
PF / PM
J2
J1