7.6. Application areas - Compatibility
-
Hydraulic oils H, HL, HLP, and HV
-
Gear oils C, CL, CLP
-
Motor oils, gas oils
-
MIL-H-5606 E
-
Vegetable oils (HTG, Triglyceride)
-
Synthetic ester (HEES)
7.7. Trouble shooting
No settings of the CCM 01 are done by the operator.
Malfunctions, which could be eliminated by the operator, are limited to cleaning the sensor
and checking cables for brakes.
Any other case requires sending in the sensor or the display unit CCM 01 to Eaton
Technologies GmbH in order to recover the functions.
A brief description of the problem would expedite the trouble shooting and the repair
process. To check your warranty and to answer questions by phone we need the serial
number and the date of purchase of the instrument.
7.8. Shipment
Article no.:
(1) Monitor CCM 01
327153
(2) Sensor PFS 01
327213
(3) Sensor cabel, L = 5 m
327320
(4) RS232
– connecting plug
335649
(5) RS232
– connecting cable
326762
(6) Data manager CD
327284
(7) Instruction manual
Optional:
1. Voltage supply 24 V, 625 mA
329932
2. Waterproof data cable (fixed connected)
329931
3. EBT 01
334002
4. Printer
338250
5. USB to RS232 adaptor plug
336300
For more information:
WEB: FLTR.com.au PHONE: (+61) 1300 62 4020 EMAIL: [email protected] SKYPE: Purple.Engineering