background image

3

1.7   Check gland pilot and bolt holes to ensure they are adaptable 

to the equipment and are the same as shown on the assembly 

drawing.

1.8    Handle all seal parts with care, they are manufactured to precise  

tolerances. The seal faces; rotating face and stationary face, are 

of special importance. These two sealing faces are lapped flat to 

within three light bands (34.8 millionths of an inch).  

 

Keep the seal faces perfectly clean at all times

1.9  Do not use oil or silicone lubricant on the shaft or sleeve of this   

friction driven seal. Use water or a mild water soluble soap solution 

to ease installation.  

2    Installation on Single End Suction Vertical Split Case 

and Vertical In-Line Pumps (1 seal chamber)

2.1   Lubricate one of the two stationary face seat gasket O-rings 

with water or mild water soluble soap solution and nest this O-ring 

in the gland cavityPress the stationary face into the gland 

with the sealing face orientated toward the inboard side of the 

gland. Use hand pressure only. Position the gland over the shaft 

or sleeve with the sealing face orientated toward the seal chamber 

(stuffing box). Place the gland as close to the bearing bracket as 

possible. Do not bump the stationary face against the shaft as it 

may chip, crack, or break.

2.2    Lubricate the shaft or sleeve with water or soap solution.
2.3  Install the rotating seal parts on the shaft or sleeve one piece  

at a time:   

 

 

 

 

 

 

•  Outer rotating face with rotating face gasket O-ring.  

•  Single coil spring

     

•  Inner rotating face with rotating face gasket O-ring.

The rotating seal parts should be as close to their final axial position as 

possible with the rotating face sealing surfaces facing away from the 

spring and toward the stationary face sealing surfaces. 
2.4  Lubricate the seal chamber bore with water or soap solution.  

The seal chamber is usually the stuffing box contained in the  

 

pump back plate.

Summary of Contents for Durametallic Double CRO

Page 1: ...Installation Instructions Experience In Motion Durametallic Double CRO Dual single coil spring friction drive for applications with water lubrication properties...

Page 2: ...worn components Clean all piping plans 1 4 Check requirements for shaft sleeve and seal housing See Figure 1 To first obstruction Face of seal housing to be square to the axis of the shaft to within...

Page 3: ...ring in the gland cavity Press the stationary face into the gland with the sealing face orientated toward the inboard side of the gland Use hand pressure only Position the gland over the shaft or slee...

Page 4: ...only be torqued to establish a leak tight seal at the gland gasket Proper land bolt adjustment is especially important with clamp style inserts where torque may damage the insert In this case gland st...

Page 5: ...nd with the stationary sealing face orientated toward the inboard side of the gland Use hand pressure only Wipe the sealing face clean with alcohol 3 6 Position the gland over the shaft or sleeve with...

Page 6: ...e seal runs hot above 51 C 120 F or squeals shut down the pump immediately as not to damage the seal Check to see if the barrier water supply is working properly If barrier water system is working cor...

Page 7: ...ting Faces Spring Rotating Face Gasket O rings Gland Gaskets Stationary Faces Stationary Face Seat Gasket O rings gland gasket gland seat gasket O ring stationary face rotating face rotating face gask...

Page 8: ...rain its employees and contractors in the safe use of Flowserve products in connection with the specific application While the information and specifications contained in this literature are believed...

Reviews: