background image

2.5    Lubricate the other stationary face seat gasket O-ring with 

water or soap solution and place this O-ring on the back shoulder 

of the remaining stationary face. Slide the inner stationary face 

with the O-ring into position at the bottom of the chamber.  

2.6    Wipe the seal faces clean with alcohol. Seal faces should not be  

lubricated but should be left clean and dry.

Caution:  Consult material safety data sheets for proper handling  

 

 

  of alcohol.

2.7    Install the seal chamber (pump back-plate) and assemble  

the  pump. Position the gland to the face of the seal housing.  

Be sure the gland pilot is properly engaged. Tighten the gland 

stud nuts evenly, cross stagger the adjustment of the nuts.  

Follow the equipment manufacturer’s recommendation for gland 

stud nut   torque. In the absence of recommendations, gland stud 

nuts should only be torqued to establish a leak tight seal at the 

gland gasket. Proper land bolt adjustment is especially important 

with clamp style inserts where torque may damage the insert.  

In this case, gland stud nuts should be torqued to a maximum  

of 13.5 N-m (10 ft-lbs).

2.8    See section 4, Operational Recommendations, before starting  

pump.

3    Double Suction and Multistage Horizontal Split Case  

Pumps (2 seal chambers)

4

Note:  The parting gasket between the upper and lower sections of  

 

the pump casing must be flush with the seal chamber bore and face  

or leakage will occur past the O-rings and gaskets.
3.1    Lubricate the shaft or sleeve and the seal chamber bore with  

water or a mild water soluble soap solution.

3.2   Lubricate one stationary face seat gasket O-ring with water  

or soap solution and place this O-ring on the back shoulder of the 

inner stationary face. Slide the stationary face with the O-ring into 

position at the bottom of the chamber. Do not bump the stationary 

face against the shaft as it may chip, crack, or break.

Summary of Contents for Durametallic Double CRO

Page 1: ...Installation Instructions Experience In Motion Durametallic Double CRO Dual single coil spring friction drive for applications with water lubrication properties...

Page 2: ...worn components Clean all piping plans 1 4 Check requirements for shaft sleeve and seal housing See Figure 1 To first obstruction Face of seal housing to be square to the axis of the shaft to within...

Page 3: ...ring in the gland cavity Press the stationary face into the gland with the sealing face orientated toward the inboard side of the gland Use hand pressure only Position the gland over the shaft or slee...

Page 4: ...only be torqued to establish a leak tight seal at the gland gasket Proper land bolt adjustment is especially important with clamp style inserts where torque may damage the insert In this case gland st...

Page 5: ...nd with the stationary sealing face orientated toward the inboard side of the gland Use hand pressure only Wipe the sealing face clean with alcohol 3 6 Position the gland over the shaft or sleeve with...

Page 6: ...e seal runs hot above 51 C 120 F or squeals shut down the pump immediately as not to damage the seal Check to see if the barrier water supply is working properly If barrier water system is working cor...

Page 7: ...ting Faces Spring Rotating Face Gasket O rings Gland Gaskets Stationary Faces Stationary Face Seat Gasket O rings gland gasket gland seat gasket O ring stationary face rotating face rotating face gask...

Page 8: ...rain its employees and contractors in the safe use of Flowserve products in connection with the specific application While the information and specifications contained in this literature are believed...