![FlowLine EchoPod UG01-03 Manual Download Page 17](http://html1.mh-extra.com/html/flowline/echopod-ug01-03/echopod-ug01-03_manual_2308254017.webp)
MN310140 Rev A2
17
|
Configuration Using WebCal
®
(continued)
Step Three
USB
®
FOB INTERFACE
EchoPod
®
communicates with WebCal
®
* through a USB
®
interface called a Fob. Before plugging your Fob
(LI99-2001) into your computer’s USB
®
port, be sure that you have installed WebCal
®
(see
www.flowline.com/webcal-software/
) on your computer.
Connect the red, green, white and black wires from EchoPod
®
into the correct terminals on the Fob. Tighten
the screws on the terminals. Plug your Fob into the USB
®
port of your computer.
Wiring to Fob (LI99-2001)
LI99-2001 USB
®
Fob
Wiring is identical for all EchoPod
®
Series – Use only the Red, Black, Green and White wires.
The
maximum cable distance
between the computer and EchoPod
®
is
15’
. This only applies for
configuring the EchoPod
®
.
Once EchoPod
®
is configured and prior to installation, isolate the white and green terminals from active
power to prevent a short from the configuration circuit.
Note: When using the Fob, do not add VDC or VAC power. The Fob, when connected to the computer, will
provide the required power to the EchoPod
®
.
Note: When connecting the sensor to the WebCal
®
Software, you must remove the display or the software
will not connect. Once completed, you can re-connect the display to the terminal.
* For complete information on the WebCal
®
software, please refer to the WebCal
®
manual located at
www.flowline.com/webcal-software/
.
Note: Only use the LI99-
2001 USB
®
Fob (white).
The LI99-1001 USB
®
Fob
(black) will not work with
the EchoPod
®
series.