Annex
9
gas-net
C1 and C2
Page 9-3
Error
number
S5/S7 Error
designation
Cause of error
00H
------------
OK telegram after SEND
0CH
Memory access
-
A data block has been addressed, which does
not correspond with the data block of an RK512
job.
-
The first addressed data word is not within the
data area of the addressed data block.
-
The addressed data is longer than the
addressed data block.
10H
Instruction 2
The second instruction letter is wrong. Here, only 'D'
for DB is permitted.
11H Access
not
permitted
A telegram with data has been sent, but no access
rights for its DB/DW area exist.
16H
Instruction 1
The first instruction letter is wrong. Only 'A' for SEND
and 'E' for FETCH are admissible.
34H Telegram
length
-
The telegram that arrived was incomplete (not
enough data).
-
The length stated in the SEND telegram and the