GW-GNET+
4
gas-net
C1 and C2
Page 4-3
8. Connect the DSS data interface at the device to a COM computer interface
using a parameterisation cable.
9. Turn the user switch at the device to “open”.
10. Mark the parameter data record and select the
Data – Export
menu item
from the main or context menu of GAS-WORKS.
11. The communication program starts.
The window appearing on your monitor shows the information
Data trans-
mission to gas-net device
.
After the transmission has been finished, the device will be restarted. The
message
Data transmission to gas-net device
disappears from the com-
munication window. The type plate of the connected
gas-net
device is
shown instead, indicating the most important device data.
You can close the communication program now.
4.2 Importing and editing a parameterisation:
Brief description
You can read out the current parameterisation of a
gas-net
device via the data
interface and edit it afterwards.
The following description explains how to read the parameterisation into your
computer:
1. Connect the COM interface of the computer to the DSS interface at the
gas-
net
device using a parameterisation cable.
2. Start GAS-WORKS on your computer if it has not been started already.
Activate the communication program by clicking the
Import – Data inter-
face
tool in the GW-BASE toolbar.
After having successfully started the communication program you are linked with
the connected device data technology-wise. The window appearing on your
monitor shows some important basic device information.
3. Select
the
Content
tab now.
4. Mark
the
Parameterisation
data record, and click the lantern icon.
A
Save as
dialog box appears asking for the name under which the data
record shall be saved in GAS-WORKS.
After you have entered the name and confirmed your entry by clicking OK,
the reading in of the data will start.