Troubleshooting 15

   

SYMPTOM 

POSSIBLE CAUSE(S) 

CORRECTIVE ACTION

  Motor will not run 

Disconnect switch is off 

Be sure switch is on.

    

Fuse is blown or circuit breaker tripped 

Replace fuse or reset circuit breaker.

    

Wires at motor are loose,  

DISCONNECT POWER; check and tighten all wiring. 

  

disconnected, or wired incorrectly  

  

    

 

   

Pressure switch contacts are dirty 

DISCONNECT POWER and clean the electrical contacts.

  Motor runs hot and  

Voltage is too low 

Check with power company. Install heavier wiring if wire size is too small.

  overload kicks off 

Pump cycles too frequently 

See section below on too frequent cycling.

  Motor runs but no  

Pump in new installation did  

In new installation: 

  water is delivered* 

not pick up prime through:  

    

  1. Improper priming  

  1. Re-prime according to instructions. 

    

  2. Air leaks 

  2. Check all connections on suction line with

   

 

      shaving cream.

    

  3. Leaking foot valve or check valve 

  3. Replace foot valve or check valve.

    

Pump has lost prime through: 

In installation already in use: 

     

  1. Air leaks 

  1. Check all connections on suction line and well seal. 

    

  2. Water level below suction pipe inlet 

  2. Lower suction line into water and re-prime. If receding water level  

    

  

      in well exceeds 16’ (5M), a deep well pump is needed.

   

Foot valve or strainer is plugged 

Clean foot valve or strainer.

   

Ejector or impeller is plugged 

Clean ejector or impeller (See Repair Parts page).

   

Check valve or foot valve is stuck shut  

Replace check valve or foot valve.

    

Pipes are frozen 

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

    

Foot valve and/or strainer are  

Raise foot valve and/or strainer above bottom of water source. 

    

buried in sand or mud 

Clean foot valve and strainer.

   

Water level is too low for shallow well   

A deep well pump may be needed (over 16’ (5M) to water)  

   

setup to deliver water 

to deliver water.

  Pump does not  

Water level in well is lower than  

A deep well jet will be needed if your well is more than 16’ (5M) 

  deliver water to full  

estimated 

depth to water.

  capacity 

Steel piping (if used) is corroded or  

Replace with plastic pipe where possible, otherwise with new steel pipe. 

   

limed, causing excess friction

    

Piping is too small in size 

Use larger piping.

  Pump delivers water but 

Pressure switch is out of adjustment or 

DISCONNECT POWER; adjust or replace pressure switch. 

  does not shut off or 

contacts are welded together

  pump cycles too 

Faucets have been left open 

Close faucets.

  frequently 

Standard pressure tank is waterlogged 

Drain tank to air volume control port. Check AVC for defects. Check 

   

and has no air cushion 

all connections for air leaks.

   

Pipes leak 

Check connections.

   

Foot valves leak 

Replace foot valve.

   

Air charge too low in pre-charged tank 

DISCONNECT POWER and open faucets until all pressure is relieved.

   

 

Using tire pressure gauge, check air pressure in tank at valve stem  

   

 

located on the tank. If necessary, adjust air pressure in tank to 1.5 Bars 

   

 

(22 psi). Check air valve for leaks (use shaving cream) and replace core   

   

 

if necessary.

  Air spurts from faucets 

Pump is picking up prime 

When pump has picked up prime, it should pump solid water with no air.

   

Leak in suction side of pump 

Suction pipe is sucking air. Check joints for leaks with shaving cream.

   

Well is gaseous 

Consult factory about installing a sleeve in the well.

   

Intermittent over-pumping of well 

Lower foot valve if possible, otherwise restrict pump discharge.

    

(Water drawn down below foot valve)

 

* (Note: Stop pump; 

then check prime 

before looking 

for other causes. 

Unscrew priming 

plug and see if water 

is in priming hole).

Summary of Contents for FP6005

Page 1: ...Espa ol Pages 2 9 Installation Operation Parts For further operating installation or maintenance assistance Call 52 899 864 3203 English Pages 10 16 Importado por PENTAIR FLOW TECHNOLOGIES DE MEXICO...

Page 2: ...El rea de trabajo se debe mantener limpia ordenada y con iluminaci n adecuada guarde debidamente las herramientas y el equipo que no utilice Mantenga a los visitantes a una distancia segura de las re...

Page 3: ...s de aire en la bomba t Las uniones deben ser herm ticas y estancas Si la tuber a de aspiraci n puede aspirar aire la bomba no podr levantar agua de la fuente de suministro de agua Usted acaba de term...

Page 4: ...cione la bomba para determinar la causa baja tensi n impulsor obstruido etc Potencia kw HP Volts Corriente Maxima Nivel de Amperaje del Fusible 370 1 2 115 6 6 15 370 1 2 220 3 8 15 560 3 4 115 7 9 15...

Page 5: ...2 5 PSI Gira en contra de las manecillas del reloj para bajar los ajustes de presi n 4 Para incrementar solo la presi n de paro gire la tuerca de ajuste 2 a favor de las manecillas del reloj Cada giro...

Page 6: ...a bomba haya aumentado la presi n en el sistema y se haya apagado verifique el funcionamiento del man stato abriendo uno o dos grifos y dejando cor rer suficiente agua como para descargar la presi n h...

Page 7: ...iva El tama o de la tuber a es muy peque o Se necesitar un chorro para pozos profundos si la profundidad de su pozo es mayor que 16 pies 5 m al agua Reemplace con tuber a de pl stico donde sea posible...

Page 8: ...y 1 200F0100 200F0100 2 Tap n de cebadura Priming Plug 1 100A0115 100A0115 3 Impulsor Impeller 1 200F0400 200F0400 4 Clip en C C Clip 1 200A0300 200A0300 5 Arandela Washer 1 200A0301 200A0301 6 Sello...

Page 9: ...ar un peligro de contaminaci n Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de co...

Page 10: ...em components Wear safety glasses at all times when working on pumps Keep work area clean uncluttered and properly lighted store properly all unused tools and equipment Keep visitors at a safe distanc...

Page 11: ...ump high spots can cause air pockets which can air lock the pump Seal the suction pipe joints with PTFE pipe thread sealant tape Joints must be air tight and water tight If the suction pipe can suck a...

Page 12: ...Volts Max Load Amp Branch Fuse Rating Amp 370 1 2 115 6 6 15 370 1 2 220 3 8 15 560 3 4 115 7 9 15 Pressure Switch Wiring The pressure switch is pre wired to the motor 1 Unplug the pump to remove pow...

Page 13: ...hange the pressure setting 0 17 Bar 2 5 PSI Turn the adjustor counterclockwise to lower the pressure setting 4 To raise only the cut off pressure turn pressure adjus tor 2 clockwise Each turn will cha...

Page 14: ...After the pump has built up pressure in the system and shut off check the pressure switch operation by opening a faucet or two and running enough water out to bleed off pressure until the pump starts...

Page 15: ...e and strainer Water level is too low for shallow well A deep well pump may be needed over 16 5M to water setup to deliver water to deliver water Pump does not Water level in well is lower than A deep...

Page 16: ...pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local...

Reviews: