4.  Place the pump in the sump; make sure that 

nothing interferes with switch operation.

5.  Finish installing the necessary plumbing. 

Follow the glue manufacturer’s instructions for 

safety precautions and curing time.

 Risk of flooding. Make sure the pump 

cannot move in the sump. If the pump moves 

when it runs, the piping or sump wall may 

interfere with the switch and prevent the pump 

from starting or stopping.

6A. Power Supply: This pump requires a 115V., 

60 Hz., 15 amp individual branch circuit. 

The circuit must be grounded and should be 

dedicated to the sump pump.

6B. The pump is supplied with a 3-wire cord set 

with grounding-type plug. Plug the switch 

directly into the outlet and plug the pump into 

the switch’s plug.

 Electrical shock hazard. Always 

ground the pump to a suitable electrical ground, 

such as a grounded water pipe, a properly 

grounded metallic raceway, or a ground wire 

system. Do not cut off the round ground pin.

7A. After you have installed the piping, check 

valve, and float switch, the pump is ready for 

operation.

7B. Check the pump by filling the sump with water 

and observing the pump’s operation through 

one complete cycle. For switch settings see 

Electrical and Switch Specifications.

 Risk of flooding. Failure to make 

this operational check may lead to improper 

operation, premature failure, and flooding.

The IntelliShield™ Switch

NOTICE: Keep the IntelliShield control box dry 

at all times. Do not connect it to an extension 

cord or let it get into the sump pit.
The IntelliShield switch consists of three stainless 

steel rods (probes) mounted vertically on the 

side of the pump . These are the OFF, ON, and 

GROUND probes (see Figure 9).
Normal Operation
When the water level rises to the level of the 

ON probe (the short stainless rod), the pump 

starts. As the pump runs, the water level drops. 

When it drops below the tip of the OFF probe 

(the long stainless rod with the long plastic 

sleeve), the pump stops.

 

Figure 6

Sump Lid omitted 

for clarity.

Figure 8

 

Sump Lid omitted 

for clarity.

Figure 7

 

Sump Lid omitted 

for clarity.

Summary of Contents for E100ELT

Page 1: ...ges 2 9 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 10 17 Instalaci n Operaci n Piez...

Page 2: ...he pump before handling or servicing it If your basement floor is wet turn off all power before walking on it If the shut off box is in the basement call your electric company or hydro authority to sh...

Page 3: ...Be sure the hole is below the waterline and below the check valve 2D To reduce noise and vibration cut the discharge pipe near the pump and fasten a short length of rubber hose 1 7 8 48 mm I D e g rad...

Page 4: ...ground wire system Do not cut off the round ground pin 7A After you have installed the piping check valve and float switch the pump is ready for operation 7B Check the pump by filling the sump with w...

Page 5: ...To replace the switch push it back between the bracket tabs until it is flat against the back of the bracket see Figure 11 Maintenance Whenever the pump is removed from the pit be sure to unplug the...

Page 6: ...y 1 PS17 1560 4 Impeller 1 PS5 35P NOTICE If motor fails replace entire pump See Page 8 for impeller replacement instructions Sump Pit Check Valve Install Vertically Basement Floor Discharge Pipe Lift...

Page 7: ...nplug the pump remove it from the sump and clean the pump and piping Restricted intake screen Unplug the pump remove it from the sump and clean the intake screen and impeller Pump operates but deliver...

Page 8: ...with a screwdriver and unscrew the impeller as shown NOTICE The impeller has a left hand thread so it loosens to the right Step 3 Thread the new impeller onto the motor shaft as shown left hand thread...

Page 9: ...Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump Fo...

Page 10: ...pompe avant de la manipuler ou de l entretenir Si le plancher du sous sol est humide ne pas marcher dessus tant que le courant n aura pas t coup Si le coffret des disjoncteurs se trouve au sous sol ap...

Page 11: ...pompe Poser le clapet antiretour au dessus de ce trou et aussi pr s que possible de la pompe S assurer que le trou est plus bas que la ligne d eau et que le clapet antiretour 2D Pour r duire le bruit...

Page 12: ...e fils de mise la terre Ne jamais couper la broche ronde de mise la terre 7A Apr s avoir branch la tuyauterie le clapet antiretour et l interrupteur flotteur la pompe est pr te fonctionner 7B V rifier...

Page 13: ...e 11 Pour reposer l interrupteur le pousser entre les attaches du support jusqu ce qu il repose plat contre l arri re du support se reporter la Figure 11 Entretien Lorsque la pompe est sortie du puisa...

Page 14: ...Sur de grandes longueurs de tuyaux le frottement de l eau circulant dans les tuyaux diminuera le d bit 5 9 Tuyau de refoulement Plancher du sous sol Puisard Refoulement Clapet antiretour installer ver...

Page 15: ...sale Essuyer l interrupteur l aide d un chiffon propre La pompe d marre et s arr te trop souvent Circulation contre courant de l eau dans les tuyaux Poser un clapet antiretour ou remplacer l ancien In...

Page 16: ...l impulseur comme illustr AVIS Le filetage de l impulseur gauche il faut donc le tourner droite pour le d visser tape 3 Visser l impulseur neuf sur l arbre du moteur comme il est illustr filetage gauc...

Page 17: ...mpes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fi...

Page 18: ...i n o mantenimiento Si el piso de su s tano est mojado desconecte la corriente el ctrica antes de caminar sobre el mismo Si la caja de desconexi n est en el s tano llame a su empresa o autoridad de se...

Page 19: ...de retenci n por encima de este orificio pero mant ngalo tan cerca de la bomba como sea posible Verifique que el orificio se encuentre debajo de la l nea de agua y por debajo de la v lvula de retenci...

Page 20: ...haber instalado la tuber a la v lvula de retenci n y el interruptor de flotador la bomba estar lista para funcionar 7B Inspeccione la bomba llenando el sumidero de agua y observando su funcionamiento...

Page 21: ...Para volver a colocar el interruptor emp jelo hacia atr s entre las leng etas del soporte hasta que haya quedado plano contra la parte posterior del soporte ver la Figura 11 Mantenimiento Siempre que...

Page 22: ...corre a trav s de la tuber a tambi n reducir el flujo en trayectos largos de tuber a 5 Piso del s tano Levante altura Foso de recogida Tuber a de descarga V lvula de retenci n instalar verticalmente...

Page 23: ...ario reemplace el impulsor Interruptor sucio Limpie el interruptor con un pa o limpio La bomba se enciende y se detiene con demasiada frecuencia Retroflujo de agua desde la tuber a Instale o reemplace...

Page 24: ...on un destornillador y destornille el impulsor seg n se ilustra AVISO El impulsor tiene una rosca izquierda de manera que se afloja hacia la derecha Paso 3 Enrosque el nuevo impulsor en el eje del mot...

Page 25: ...ienda minorista Comun quese con el Departamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si...

Page 26: ......

Page 27: ......

Page 28: ......

Reviews: