background image

Specifications and Safety 

2

For parts or assistance, call Flotec Customer Service at 1-800-365-6832

Description

This submersible sump pump is designed for 

home sumps. The permanent split capacitor 

motor is oil filled, sealed for cooler running, 

and has automatic-reset thermal protection. 

Ball bearings on the motor shaft never need 

lubrication. The power cord is a 3-wire, 

grounding-type cord.

Specifications

Power supply ...................... 115V, 60 HZ., 15 Amp Circuit
Liquid Temp. Range ......................... 32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ............15 Amps
Discharge: ............................................1-1/2” Female NPT

This pump is designed for use in a residential 

sump only. Pump water only with this pump.
NOTICE: This unit is not designed as a waterfall, 

pond, or fountain pump, or for applications 

involving salt water or brine! Use with waterfalls, 

fountains, salt water or brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool 

drainer.
NOTICE: Read this Owner’s Manual for 

installation, operation, and safety information.

General Safety Information

Your automatic sump pump should give years 

of trouble-free service when correctly installed, 

maintained, and used. However, interruption 

of power to the pump, dirt/debris in the sump, 

flooding that exceeds the pump’s capacity, 

electrical or mechanical failure in the pump, 

etc., may prevent normal pump operation. To 

help prevent damage from flooding, purchase 

a secondary AC sump pump, a DC backup 

sump pump, and/or a high water alarm. See 

Troubleshooting in this manual for information 

about common sump pump problems and 

remedies. For more information,call Flotec 

customer service at 1-800-365-6832.

 Hazardous voltage. To reduce the 

risk of hazardous or fatal electrical shock, follow 

instructions A through D, below:
A.  This pump has an approved 3-conductor 

power cord with 3-prong, grounding-type plug. 

Connect the pump only to a properly grounded, 

3-prong outlet. If the sump pump circuit has 

a 2-prong outlet, replace it with a grounded 

3-prong outlet installed according to code.

B.  Unplug the pump before handling or servicing 

it. If your basement floor is wet, turn off all 

power before walking on it. If the shut-off box 

is in the basement, call your electric company 

or hydro authority to shut off service to the 

house, or call your local fire department 

for instructions. After turning off the power, 

remove the pump for service.

C.  Protect the electrical cords from sharp objects, 

hot surfaces, oil, and chemicals. Avoid kinking 

the cords. Replace damaged or worn cords.

D.  Do not lift the pump by the power cord.

 Risk of fire. Plastic pipe glue 

is extremely flammable. Follow the glue 

manufacturer’s instructions when assembling 

glued plastic pipe.

 Burn hazard. Motors may run hot. 

Allow 20 minutes to cool before handling.
1.  Know the pump application, limitations, and 

potential hazards.

2.  Do not use this pump in water with fish 

present. If any oil leaks out of the motor it can 

kill fish.

3.  Drain the system completely before servicing it.
4.  To prevent a flexible discharge line from 

whipping, which could cause injury or 

damage, fasten it down before starting the 

pump.

5.  Before each use, check any hoses in the system 

for weakness or wear. Make certain that all 

connections are tight.

6.  Periodically inspect the sump, the pump, 

and the piping for debris and foreign objects. 

Perform routine cleaning as required.

7.  Personal Safety:

a.  Wear safety glasses at all times when 

working with pumps.

b.  Keep your work area clean, uncluttered 

and properly lighted; put away all unused 

tools and equipment.

c.  Keep visitors at a safe distance from the 

work area.

d.  Make workshop child-proof with padlocks 

and master switches. Remove any starter 

keys.

8.  This pump installation must meet all applicable 

laws, codes, and ordinances.

Tools Required:
Pipe wrench, Strap Wrench, or Slip-Joint Pliers,
Hacksaw,
Screw Driver,
File or Sandpaper
Materials Required:
1-1/2” ABS or PVC Pipe with Cement to match
Threaded Adapter (Pipe to Pump)
Check Valve – Purchase a check valve that goes 

in the discharge line or in the pump discharge. 

If your check valve does not have an 1/8” anti-

airlock hole, drill one in the discharge pipe just 

above where it screws into the pump discharge. Be 

sure to install the check valve so that the flow 

will be away from the pump.

Summary of Contents for E100ELT

Page 1: ...ges 2 9 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 10 17 Instalaci n Operaci n Piez...

Page 2: ...he pump before handling or servicing it If your basement floor is wet turn off all power before walking on it If the shut off box is in the basement call your electric company or hydro authority to sh...

Page 3: ...Be sure the hole is below the waterline and below the check valve 2D To reduce noise and vibration cut the discharge pipe near the pump and fasten a short length of rubber hose 1 7 8 48 mm I D e g rad...

Page 4: ...ground wire system Do not cut off the round ground pin 7A After you have installed the piping check valve and float switch the pump is ready for operation 7B Check the pump by filling the sump with w...

Page 5: ...To replace the switch push it back between the bracket tabs until it is flat against the back of the bracket see Figure 11 Maintenance Whenever the pump is removed from the pit be sure to unplug the...

Page 6: ...y 1 PS17 1560 4 Impeller 1 PS5 35P NOTICE If motor fails replace entire pump See Page 8 for impeller replacement instructions Sump Pit Check Valve Install Vertically Basement Floor Discharge Pipe Lift...

Page 7: ...nplug the pump remove it from the sump and clean the pump and piping Restricted intake screen Unplug the pump remove it from the sump and clean the intake screen and impeller Pump operates but deliver...

Page 8: ...with a screwdriver and unscrew the impeller as shown NOTICE The impeller has a left hand thread so it loosens to the right Step 3 Thread the new impeller onto the motor shaft as shown left hand thread...

Page 9: ...Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump Fo...

Page 10: ...pompe avant de la manipuler ou de l entretenir Si le plancher du sous sol est humide ne pas marcher dessus tant que le courant n aura pas t coup Si le coffret des disjoncteurs se trouve au sous sol ap...

Page 11: ...pompe Poser le clapet antiretour au dessus de ce trou et aussi pr s que possible de la pompe S assurer que le trou est plus bas que la ligne d eau et que le clapet antiretour 2D Pour r duire le bruit...

Page 12: ...e fils de mise la terre Ne jamais couper la broche ronde de mise la terre 7A Apr s avoir branch la tuyauterie le clapet antiretour et l interrupteur flotteur la pompe est pr te fonctionner 7B V rifier...

Page 13: ...e 11 Pour reposer l interrupteur le pousser entre les attaches du support jusqu ce qu il repose plat contre l arri re du support se reporter la Figure 11 Entretien Lorsque la pompe est sortie du puisa...

Page 14: ...Sur de grandes longueurs de tuyaux le frottement de l eau circulant dans les tuyaux diminuera le d bit 5 9 Tuyau de refoulement Plancher du sous sol Puisard Refoulement Clapet antiretour installer ver...

Page 15: ...sale Essuyer l interrupteur l aide d un chiffon propre La pompe d marre et s arr te trop souvent Circulation contre courant de l eau dans les tuyaux Poser un clapet antiretour ou remplacer l ancien In...

Page 16: ...l impulseur comme illustr AVIS Le filetage de l impulseur gauche il faut donc le tourner droite pour le d visser tape 3 Visser l impulseur neuf sur l arbre du moteur comme il est illustr filetage gauc...

Page 17: ...mpes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fi...

Page 18: ...i n o mantenimiento Si el piso de su s tano est mojado desconecte la corriente el ctrica antes de caminar sobre el mismo Si la caja de desconexi n est en el s tano llame a su empresa o autoridad de se...

Page 19: ...de retenci n por encima de este orificio pero mant ngalo tan cerca de la bomba como sea posible Verifique que el orificio se encuentre debajo de la l nea de agua y por debajo de la v lvula de retenci...

Page 20: ...haber instalado la tuber a la v lvula de retenci n y el interruptor de flotador la bomba estar lista para funcionar 7B Inspeccione la bomba llenando el sumidero de agua y observando su funcionamiento...

Page 21: ...Para volver a colocar el interruptor emp jelo hacia atr s entre las leng etas del soporte hasta que haya quedado plano contra la parte posterior del soporte ver la Figura 11 Mantenimiento Siempre que...

Page 22: ...corre a trav s de la tuber a tambi n reducir el flujo en trayectos largos de tuber a 5 Piso del s tano Levante altura Foso de recogida Tuber a de descarga V lvula de retenci n instalar verticalmente...

Page 23: ...ario reemplace el impulsor Interruptor sucio Limpie el interruptor con un pa o limpio La bomba se enciende y se detiene con demasiada frecuencia Retroflujo de agua desde la tuber a Instale o reemplace...

Page 24: ...on un destornillador y destornille el impulsor seg n se ilustra AVISO El impulsor tiene una rosca izquierda de manera que se afloja hacia la derecha Paso 3 Enrosque el nuevo impulsor en el eje del mot...

Page 25: ...ienda minorista Comun quese con el Departamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si...

Page 26: ......

Page 27: ......

Page 28: ......

Reviews: