Temperature ranges
-40–+120 °C (-40–+248 °F)
-10–+55 °C (+14–+131 °F)
0–+500 °C (+32–+932 °F)
NOTE:
Depending on your camera
configuration, one of these ranges may be
disabled.
Temperature range, standard
Up to +1000 °C (+1832 °F)
Temperature range, optional
± 2 °C/± 3.6 °F or ± 2 % of reading
Accuracy
Set by number, or by selection in predefined list
Emissivity correction
Automatic, based on input from distance, at-
mospheric temperature, and relative humidity.
Atmospheric transmission correction
Automatic, based on signals from internal sen-
sors
Optics transmission correction
Yes
Reflected ambient temperature correction
Yes
External optics correction
14.5
Electrical power system
Rechargeable Li/Ion battery
Battery type
1.5–2 hours. Display shows battery status
Battery operating time
In camera (AC adapter) or stand-alone 2-bay
charger
Battery charging
AC adapter, 90–260 VAC, 50/60 Hz, 12 VDC out
AC operation
9–16 VDC (11–16 VDC when charging)
Voltage
User-selectable:
■
automatic shut-down
■
stand-by
■
sleep and
■
deep-sleep mode
Power management
14.6
Environmental specifications
-15–+50 °C (+5–+122 °F)
Operating temperature range
66
Publ. No. 1 557 536 Rev. a35 – ENGLISH (EN) – January 20, 2004