427-0100-00-12 Version 100
December 2018
10
The information contained herein does not contain technology as defined by EAR,15 CFR772, is publicly available, and therefore not subject to EAR.
Installation
1.2.8
Install the Back Box
Step 1
For each cable, use the Torx wrench to punch a hole in the center of the grommet from the
underside. Insert the cable from the conduit though the hole.
Punch through grommet
from underside here
For surface mount
remove with
Torx wrench
Step 2
Push cables back through the seal so the seal is extended out of the back box, as shown:
Wrong
Correct
Inside back box
Step 3
Seal all exposed connections. Cable connections are not waterproof.
Connection
Purpose
Ethernet
Power and IP communications
10-pin connector
Power I/O terminal: alarm I/O, audio I/O, Vac or Vdc power
Step 4
Terminate cables and plug into connectors.
Power & I/O Connector
Pin
Connection
Notes
1
Vac/Vdc power +
12 Vdc/24 Vdc/24 Vac optional power when PoE is not
available
2
Vac/Vdc power -
3
Alarm
Relay contact: 1A max at 24 Vac/30 Vdc
4
Alarm Output -
5
Alarm Input +
Dry alarm contact
6
Alarm Input -
7
Audio In +
Support in future firmware release
8
Audio In -
9
Audio Out +
1 V P-P line level, connect to amplified speaker
10
Audio Out -