427-0089-00-12 Version 100
July 2016
18
1
Camera Installation
Step 6
As needed, clean the o-ring and the o-ring
groove in the bottom of the camera using
isotropy alcohol and press the o-ring into its
groove.
Step 7
For each cable, punch hole in the center of a
gland seal from the top using the 3 mm hex
key. Insert the cable from the bottom though
the hole.
Step 8
Place the gland plate back into position and
tighten the four 3 mm captive screws using a
torque value of 1.8 n-m (16.0 in-lbs).
Step 9
Check the length of each cable to ensure an
appropriate bend radius and terminate the
cable.
Step 10 Push the cable back through the gland seal so that the seal is extended down not up, as
shown in the illustration below.
Step 11
Connect the cables as indicated in
Camera Connections, pg. 11
. Ensure that any ground
wire that was removed during installation is reconnected. Replace the cover and tighten
the four 3 mm hex screws to 1.8 n-m (16.0 in-lbs).
Caution!
Step 12 Using the hex key included with the concealed cable mount, loosen the ball joint on the
bottom of the mount, position the camera as required, and then re-tighten the ball joint.
1.6
Camera specifications
When replacing the cover, make sure the ground wire between the cover and the camera body is
completely inside the o-ring groove. If the wire is pinched between the cover and the base, the
camera will not be sealed against water ingress and could be damaged.
Camera Model
FC-Series ID
Camera Platform Type
Fixed
Composite Video
NTSC or PAL
Thermal Camera
Array Format
320 x 256 (34 µm pixel pitch)
336 x 256, 640 x 512 (17 µm pixel pitch)
Detector Type
Long-Life, Uncooled VOx Microbolometer
Figure 1-16: Cable through Seal Plate
Wrong
Correct