427-0089-00-12 Version 100
July 2016
17
1
Camera Installation
Proper installation of the seal plate and panel mount gland seals is critical to long term reliability.
Cables enter the bottom of the camera enclosure through the seal plate and panel mount glands. Be
sure to insert each cable through its panel mount gland on the seal plate before terminating them
(connectors will not fit through the gland). Ensure the manufacturer’s recommended cable bend
radius is not exceeded within the enclosure.
Prepare the Camera
Step 1
Use a 3 mm hex key to loosen the four captive screws and remove the top cover as
described above.
Step 2
Remove the rear cable gland and replace it with the cable gland plug. Use the gasket and
nut that were removed with the cable gland.
Step 3
Use a 3 mm hex key to
loosen the four captive
screws and remove the
seal plate, o-ring, and
plug.
Step 4
Install the wall mount (PN
4129742) to the wall and pull the cable(s) through
the mount. Cut a small cross-slit in the black
mount gasket and push the cable(s) through the
gasket. Pull the cable(s) through the opening in
the bottom of the camera. A single Ethernet cable
is shown in the images.
Step 5
Secure the camera to the mount using four M5 x
0.8 threaded fasteners to the bottom of the
camera. Use Loctite 222 low strength thread
locker for the mount fasteners.
RG 59 Video cable
5.3 mm
[0.209 in]
10 mm
[0.394 in]
Table 1-4: Cable Min/Max Dimensions using Concealed Cable Wall Mount (PN 4129742)
Cable
Min
Max
Notes
Figure 1-13: Seal Plate Removed
Panel mount gland seals (x4)
Seal plate
Gland plug
Plug
installed
Figure 1-14: Removed Parts
Figure 1-15: Camera Mount
Mount Gasket