427-0033-00-12 Version 110
February 2019
6
This document does not contain any export-controlled information.
F
-
Series ID Camera Installation
1.3
Installation Overview
The F
-
Series ID Camera is an infrared thermal imaging camera intended for outdoor applications,
and can be installed in a fixed location or on a pan/tilt mechanism.
The F
-
Series ID
camera is intended to be mounted on a medium-duty fixed pedestal mount or wall
mount commonly used in the CCTV industry. Cables exit from the back of the camera housing. The
mount must support up to 30 lbs. (15 KG).
1.3.1
Camera Connection Options
Camera connections are made through water-tight cable gland seals on the rear of the camera.
Refer to
to ensure the glands are used correctly and the connections are
properly sealed.
The camera is powered with a conventional power supply using 21 - 30 Vac or 21 - 30 Vdc.
The F
-
Series ID camera produces both analog video and digital (IP) video output. Analog video will
require a connection to a video monitor or an analog video matrix switch.
An Ethernet connection is required for IP video streaming and for command and control
communications.
Several third-party video management systems are supported by FLIR IP cameras. Because these
systems tend to evolve and change over time, contact the local FLIR representative or FLIR
Technical Support for information.
General Purpose Input/Output (GPIO)
The camera can receive a single input signal and can provide a single output signal. Refer to
Input Signal
—When an external alarm device closes a switch to complete the circuit for the
camera, an input alarm is generated by the GPIO for the Alarm Manager.
Output Signal
—When an output alarm is generated by the Alarm Manager for the GPIO, the
camera closes its internal switch to complete the circuit for the receiving device.
Figure 1-1: F
-
Series ID Camera
Shipping plugs only -
Remove before installing